Herunterladen Inhalt Inhalt Diese Seite drucken

Ac Voltage Measurements; Resistance And Continuity Measurement - Iso-Tech ILCM 03A Bedienungsanleitung

Ac leakage current tester
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 43
a.Set the rotary switch at desired range.
b. Press the trigger to open the jaw and fully enclose only one wire.
No air gap is allowed between the two half jaws.
c. Read the measured value from the LCD display.

3.3. AC Voltage Measurements

WARNING: Maximum input for DC V is 600, and for AC V is 600. Do
not attempt to take any voltage measurement that exceeds the limits.
Exceeding the limits could cause electrical shock and damage to the
clamp meter.
a. Set the rotary switch at 400V
b. Insert the test leads into the input jack.
c. Connect the test prods of the test leads in PARALLEL to the circuit
to be measured.
d. Read the measured value from the LCD display.
WARNING:Before taking any in-circuit resistance measurement, remove
power from the circuit being tested and discharge all the capacitors.

3.4. Resistance and Continuity Measurement

3.4.1.Set the rotary switch at Ω
3.4.2.Insert the test leads into the input jack.
3.4.3.Connect the test prods of the test leads to the two ends of the
resistor or circuit to be measured.
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis