Herunterladen Inhalt Inhalt Diese Seite drucken

Connection Of The Appliance To The Flue; Evacuation Of The Combustion Products; Connection To External Air Inlets; Safety Recommendations - LA NORDICA Extraflame LP30 Benutzerhandbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 70
It is recommended that the smoke pipe be equipped with a
collection chamber for solid materials and any condensate situated
under the smoke channel inlet, so that it can be easily opened and
inspected from airtight door.

CONNECTION OF THE APPLIANCE TO THE FLUE

The fl ue must receive the discharge from only one heat generator.
The direct discharge towards closed spaces is forbidden, even
with clear sky.

EVACUATION OF THE COMBUSTION PRODUCTS

The direct discharge of the combustion products must be at
roof and the smoke pipe must have the features provided in the
"Chimney or individual fl ue" section.
< 3 m
3 - 5 %
Inspection
External pipe
that is isolated
Inspection

CONNECTION TO EXTERNAL AIR INLETS

The appliance must be able to use the necessary air to guarantee
regular functioning through external air inlet. The air inlets must
comply with the following requisites:
1. have a total free section of at least 80 cm2.
2. must be protected by grates, metal net or suitable protections as
long as they do not reduce the minimum section stated in point 1
and positioned in order to avoid them being obstructed.
If the combustion agent air is withdrawn directly from outside
through a pipe, a downward bend must be mounted outside
or a protection against the wind and no grates or similar must
be positioned. (it is recommended that the air vent always
INSTALLATION
communicates directly with the installation room even if the air
is withdrawn from outside through a pipe). The air fl ow can also
be obtained from an adjacent room, as long as the fl ow takes
place freely through permanent openings communicating with
the outside. The adjacent room, with respect to the installation
room, must not be put in depression with respect to the external
environment by means of reverse draught caused by the presence
of another used appliance or intake device in such room. The
permanent openings in the adjacent room must comply with the
above-described requisites. The adjacent room cannot be set up
as garage, storage for combustion material or activity with danger
of fi re.

SAFETY RECOMMENDATIONS

The coverings, independently from the materials from which they
are made, must constitute a self-supporting construction with
respect to the heating block and not be in contact with it. The cross
Chimney cap
members and fi nishings in wood or combustion materials must
wind-proof
be positioned outside the hearth radiation area or adequately
insulated. If coverings in combustion material or sensitive to heat
exist in the space above the generator, an insulating and non
combustible protection diaphragm must be inserted. Elements
Flue
in combustible or infl ammable material like wooden furniture,
pipe
curtains, etc., directly exposed to the hearth radiation, must be
positioned at a safe distance. The appliance installation must
guarantee easy access for cleaning the appliance itself, discharge
gas pipe and fl ue.
Inspection
< 3 m
45°
45°
Inspection
NATIONAL, REGIONAL, PROVINCIAL AND TOWN
COUNCIL REGULATIONS
It is necessary to bear in mind all laws and national, regional,
provincial and town council Standards present in the country the
appliance has been installed.
Minimum
2
80 cm
A
Floor-protection
REFERENCES
Minimum distance
A
B
C
20 cm
C
B
500 mm
700 mm
500 mm
33

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis