EN
Calculation of distance by 3 additional measurements (Sum of cathetuses)
Press
4 times
Symbol
Press
First measurement (hypotenuse 1).
Press
Second measurement (cathetus).
Press
Third measurement (hypotenuse 2).
– hypotenuse 1 (measured)
– cathetus (measured)
– hypotenuse 2 (measured)
– cathetus (calculated)
Timer
Press
Activate timer. Default value is 5 seconds.
Press
or
Adjust the timer response time.
Press
Start timer.
Memory
Enter memory. A number of saved measuring results is
Press
reflected on symbol
Press
or
Flip through saved measuring results.
18
XP3 PRO CONDTROL
User manual
appears on the display.
on the display.
LASER DISTANCE METER
EN
Bluetooth
Activate Bluetooth function.
Press
Symbol
Bluetooth in your phone, tablet PC or laptop. For
further operation please use application Smart
Measure CONDTROL.

MESSAGE CODES

While operation, the following codes/symbols may appear on the display:
Message
Cause
ERR
Out of measuring range
ERR 1
Laser signal is too weak
ERR 2
Laser signal is too strong
ERR 3
Low battery voltage.
The ambient temperature is
ERR 4
out of the working range.
Measuring error in
ERR 5
Pythagoras function.
ERR 6
Failure of tilt sensor.
XP3 PRO CONDTROL
User manual
appears on the display. Switch on
Solution
Use the device within the range.
Use the reflecting plate.
Use the reflecting plate.
Сharge or replace the batteries.
Use the device in the specified
temperature.
Measure again and ensure
that hypotenuse is bigger than
cathetus.
Please contact service center.