Herunterladen Diese Seite drucken

Cardin Elettronica CDR series Handbuch

Modulierte infrarotlichtschranke
Vorschau ausblenden Andere Handbücher für CDR series:

Werbung

CARDIN
Via Raffaello, 36- 31020 San Vendemiano (TV) Italy
Tel:
Fax:
email (Italy):
email (Europe):
Http:
ITALIANO
BARRIERA ALL'INFRAROSSO MODULATO "MINI CDR891"
AVVERTENZE
Il presente manuale si rivolge a persone abilitate all'installazione di "APPARECCHI UTILIZZATORI DI
ENERGIA ELETTRICA" e richiede una buona conoscenza della tecnica, esercitata in forma professionale.
Prima di dar inizio all'installazione prendere visione dei dispositivi di sicurezza previsti dal prodotto per
utilizzarli con la massima efficacia.
Descrizione e versioni
La barriera all'infrarosso modulato "CDR891" è composta da:
1) Una centralina di controllo CDR891
2) Uno Zoccolo per montaggio a pannello o su barra DIN46277
3) Una ottica TX con cavo schermato NERO e supporto per fissaggio a pannello.
4) Una ottica RX con cavo schermato GRIGIO e supporto per fissaggio a pannello.
La lunghezza dei cavi delle ottiche è diversa a seconda delle versioni:
Versione
Lunghezza cavo TX (Nero)
CDR891 standard
CDR891-1 (a richiesta)
CDR891-2 (a richiesta)
Possibilità di impiego
La barriera a raggio infrarosso modulato "CDR891" rappresenta un efficiente sistema di sicurezza per
la protezione di passaggi o spazi soggetti ad installazioni automatizzate di ascensori, porte o dove si
debba rilevare il passaggio o conteggio di persone o cose. Il sistema è adatto per applicazione su pas-
saggi di luce compresa fra 1 e 8 metri. L'uso e l'installazione di questa apparecchiatura deve rispettare
rigorosamente le indicazioni fornite dal costruttore e le normative di sicurezza vigenti.
INSTALLAZIONE (fig.1-4)
Attenzione! Se si installano più CDR891 è opportuno, al fine di un corretto funzionamento,
che i coni di emissione delle singole ottiche non si sovrappongano. I due raggi devono essere
distanti circa 1 metro uno dall'altro nel caso di installazioni con passaggio luce di 2 metri; 1,5
metri nel caso di installazioni con passaggio luce di 4 metri e 2 metri nel caso di installazioni con
passaggio luce di 8 metri.
1) Determinare il passaggio luce e scegliere le ottiche adatte all'installazione. Le ottiche vengono for-
nite complete di cavi che non è possibile allungare. Se invece si desidera accorciarli è preferibile
intervenire sul cavo RX cosicchè l'ottica RX risulti più vicina alla logica di controllo ricevendo così
un segnale più pulito.
N.B.: evitare di spellare il cavo schermato per più di 2cm nella connessione allo zoccolo (questo
accorgimento diminuisce la sensibilità ai disturbi esterni).
2) Verificare attentamente che le superfici sulle quali si devono fissare i supporti in plastica (fig. 3a) siano
in bolla e perfettamente affacciate fra loro in quanto non è consentita una regolazione esterna.
3) Determinare il punto in cui andrà collocata la logica di controllo tenendo conto della lunghezza delle
ottiche a disposizione; se l'installazioni avviene all'esterno dell'edificio la logica di controllo deve
essere inserita in contenitore stagno (IP55).
4) Prevedere il passaggio dei cavi di collegamento dalla logica di controllo al punto di fissaggio delle
ottiche (fig. 3b) evitando il collocamento in canalette in cui vi siano cavi ad alta tensione.
5) Calcolare le altezze ("H" fig.2) rispetto al suolo e marcare i punti di fissaggio dei supporti in plastica.
6) Utilizzando un trapano con punta da Ø12 effettuare i fori sui punti marcati (fig. 3).
7) Inserire i supporti in plastica (fig. 3a)
8) Fissare le ottiche al supporto infilando il cavo ed esercitando una pressione (fig.3b). Una volta
bloccate, le ottiche non possono essere estratte dall'esterno (garanzia contro la manomissione).
9) Qualora sia necessario sostituire l'ottica, scollegare il cavo di collegamento ed esercitare una pressione
dall'interno verso l'esterno per liberare l'ottica dal suo supporto in plastica.
10) Effettuare i collegamenti rispettando rigorosamente lo schema riportato in fig.4. La sezione minima
del cavo di alimentazione deve essere di 0,2mm
11) Selezionare la portata come indicato sulla tabella seguente.
SELEZIONE PORTATA
POSIZIONE
PORTATA INTERNO
SELETTORE
Pos. 1
Pos. 2
Pos. 3
* In qualunque condizione atmosferica
Attenzione! I dati relativi alla portata si riferiscono ad una installazione ottimale che rispetta tutti
i punti del paragrafo "Installazione".
Anomalie di funzionamento
• Il led verde è spento
- verificare il collegamento elettrico
- verificare la tensione di alimentazione (12-24Vac/dc)
• Il led rosso rimane sempre acceso
- le ottiche non sono allineate
- verificare che il raggio non è ostacolato
- verificare l'integrità delle ottiche
- verificare l'integrità dei cavi
ELETTRONICA
+39/0438.404011-401818
+39/0438.401831
Sales.office.it@cardin.it
Sales.office@cardin.it
www.cardin.it
Lunghezza cavo RX (grigio)
5 m
3 m
10 m
7 m
15 m
10 m
(AWG#24).
2
PORTATA ESTERNO*
max.
max.
2 m
1,5 m
4 m
3 m
8 m
6 m
spa
SERIAL NUMBER
ZVL232.02
This product has been tried and tested in the manufacturer's laboratory, du-
ring the installation of the product follow the supplied indications carefully.
MODULATED INFRARED BARRIER "MINI" CDR891
REMARKS
These instructions are aimed at professionally qualified "installers of electrical equipment" and must
respect the local standards and regulations in force.
Before commencing with the installation of this appliance familiarise yourself with the safety devices
required by the system, only then will you be able to use them to great effect.
Description and versions
The modulated infrared barrier "CDR891" is composed of:
1) A CDR891 control box
2) A socket DIN 46277 for fitting on panelling or rails.
3) A transmitter sensor with a "BLACK" shielded cable and wall mounting support.
4) A receiver sensor with a "GREY" shielded cable and wall mounting support.
The length of the cables differs according to the version:
Version
CDR891 standard
CDR891-1 (on request)
CDR891-2 (on request)
Use
The modulated infrared barrier "CDR891" constitutes an efficient control and safety system for the
protection of automatic installations such as lifts and automatic doors or and is suitable for controlling
passageways of from 1 to 8 metres in width.
The use and installation of these appliances must rigorously respect the indications supplied by the
manufacturer and the safety standards and regulations in force.
INSTALLATION INSTRUCTIONS (fig. 1-4)
Caution! If you install more than one CDR891, in order to guarantee the correct operation, the
emission cones of the individual sensors should not overlap.
The two beams must be separated by at least 1 m when installed in a 2 m wide passageway; 1.5 m
when installed in a 4 m wide passageway and 2 m when installed in an 8 m wide passageway.
1) Work out the passage width and choose the sensors most suitable to your installation remembering
that the sensors come complete with cables and that although it is not possible to extend the
cables you may shorten them if required (in this case it is preferable to shorten the receiver cable
so as to allow it to be nearer the control box).
Warning: Do not peel the cables back by more than 2cm when wiring up to the socket as this will
reduce the device's level of resistance to external interference.
2) Make sure that the surfaces to which the sensor supports (fig. 3a) are to be fitted are not inclined
and that they are perfectly aligned as once installed the sensors cannot be adjusted externally.
3) Work out the point at which the control box is to be fitted by taking into account the length of the ca-
bles. If the control box is to be installed outdoors it must be protected by a waterproof container (IP55).
4) Run the cables from the control box to the sensors (fig. 3b) making sure that they are not passed
through ducts containing high tension wires.
5) Work out the height ("H" fig. 2) and mark the points at which the plastic supports are to be fitted.
6) Drill a Ø12 hole at each installation point (fig. 3).
7) Insert the plastic supports (fig. 3a)
8) Fix the sensors to the supports by first inserting the cable and then pressing down on the sensor
until it snaps into position (fig. 3b). Once they have been fastened down the sensors cannot be
extracted externally (these are anti-tampering devices).
9) If you have replace the sensor; first disconnect the cable from the socket and then press from the
inside towards the outside to free the sensor from its plastic support.
10) Carry out the electrical connection exactly following the attached wiring diagram (fig. 4). The minimum
cable cross section area for the power cable is 0,2mm
11) Select the range as indicated in the following table:
RANGE SELECTION
JUMPER
POSITION
Pos. 1
Pos. 2
Pos. 3
* Under all atmospheric conditions
Attention! The range values are strictly dependent on a well executed installation which respects
all the points specified in the paragraph "Installation".
Operational anomalies
• The green led is off
- Check the electrical connection
- Check the power supply voltage (12-24Vac/dc)
• The red led remains constantly lit
- The sensors are not correctly aligned
- make sure that the beam is not interrupted
- check the integrity of the sensors
- check the integrity of the cables.
SERIES
MODEL
CDR
891
ENGLISH
Cable length TX (Black)
Cable length RX (Grey)
5 m
10 m
15 m
(AWG #24).
2
INTERNAL RANGE
EXTERNAL RANGE*
max.
2 m
4 m
8 m
DATE
17-02-2003
3 m
7 m
10 m
max.
1,5 m
3 m
6 m

Werbung

loading

Inhaltszusammenfassung für Cardin Elettronica CDR series

  • Seite 1 CARDIN ELETTRONICA SERIES MODEL DATE SERIAL NUMBER ZVL232.02 17-02-2003 Via Raffaello, 36- 31020 San Vendemiano (TV) Italy Tel: +39/0438.404011-401818 Fax: +39/0438.401831 This product has been tried and tested in the manufacturer's laboratory, du- email (Italy): Sales.office.it@cardin.it email (Europe): Sales.office@cardin.it ring the installation of the product follow the supplied indications carefully. Http: www.cardin.it ITALIANO...
  • Seite 2 DEUTSCH FRANÇAIS DEUTSCH BARRIERE A INFRAROUGE MODULE "MINI CDR891" MODULIERTE INFRAROTLICHTSCHRANKE "MINI CDR891" REMARQUE HINWEIS Ce livret est destiné à des personnes titulaires d’un certificat d’aptitude professionnelle pour Das vorliegende Handbuch wendet sich an Personen, die zur Installation von "ELEKTROGERÄTEN" befähigt l’installation des "APPAREILS ÉLECTRIQUES"...
  • Seite 3 ópticos no permiten la regulación exterior. CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831 3) Determinar el punto preciso donde se va a colocar la lógica de control teniendo en cuenta LA DISTANCE TX-RX NE DOIT PAS DÉPASSER LES 8 MÈTRES.
  • Seite 4 Schutzgrad (Optiken): ....................IP55 - Relay intervention time ...................30mS - Relaisansprechzeit: ....................30mS CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831 - Drop out delay ......................100mS - Abfallverzögerung: ....................100mS - Max commutable power at the relay load ac/dc: ..........60VA/28W - vom Relais, umschaltbare Höchstleistung Belastung: ........60VA/28W...

Diese Anleitung auch für:

Mini cdr891