Herunterladen Diese Seite drucken

Pinter MANOCOMB IP65/XI Bedienungsanleitung Seite 26

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5e.
Electrical connection
assignment for all
micro switch
switching functions
El. connection
1,2
+Ub
NC
terminal blocks
3
1
Remarks
1
assignment NC & NO vice-versa for vacuum ranges
Above assignments represent the standard
2
Check the information on the device for any special designs
1K versions calibrated for rising pressure by factory default
3
Check the information on the device for any special designs
2K versions calibrated for falling (A) and rising pressure (B) by factory default
4
Check the information on the device for any special designs
additional assignment for
GND
3
2K-versions
4
NO
+Ub
NC
NO
GND
2
6
4
5
GND
MANOCOMB®-IP65/XI Operating Instructions
5f.
Electrical data
max. permissable steady current I max [A] - ohmic load
reference switch cycle: 30/min; reference temperature: +30°C
micro switch
U [V]
24 V
48 V
Standard
I [A] AC
5
5
Standard
I [A] DC
5
2
MG
3
I [A] AC
1
1
MG
3
I [A] DC
1
0,5
inductive contact
function
I-N
NAMUR NC
I-SN
NAMUR NC
I-S1N
NAMUR NO
60 V
110 V
240 V
SD [%]
2
5
5
5
1
1
0,4
0,2
1
1
1
---
1,5
0,35
0,2
---
1,5
output polarity
SD [%]
2
NAMUR
0,5
safety function
0,5
safety function
0,5

Werbung

loading