5b.
Technical data MANOCOMB-IP65/XI
function
life cylce
low pressure ranges
normal pressure ranges
high pressure ranges
differential pressure
vacuum ranges
over pressure safety
vaccum safety
material enclosure
material wetted parts
material wetted gaskets
permissable media temperature
permissable ambient temperature
temperature deviation
switching contact
adjustment accuracy
MANOCOMB®-IP65/XI Operating Instructions
mechanical pressure switch; force balance measuring system with bellows sensors
at least 10 mio switch cycles
0 - 60 mbar to 0 - 600 mbar
0 - 1 bar to 0 - 60 bar
0 - 100 bar to 0 - 400 bar (requires wetted parts in stainless steel)
max. ration between static and differential pressure 10:1
-1...0 bar to -60...0 mbar
> 1,5x FS
-1 bar
reinforced polycarbonate; transparent cover
brass or stainless steel 1.4571 (AISI 316Ti) / 1.4404 (AISI 316L)
FKM or welded measuring system (only stainless steel version)
-20...+80°C (+130°C for stainless steel version)
-20...+80°C
approx. 1% per 20°C
1 or 2 switching contacts (for details please see electrical data)
< 1,0% FS