Herunterladen Diese Seite drucken

Grohe 43 586 Montageanleitung Seite 3

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Please leave these instructions at the solenoid valve
GB
Solenoid valve for:
Time control electronic / Infra-red electronic in Urinal Row installations
Function
When the user stands in the reception zone of the infra-red light, a diode receives a reflected signal which
is transmitted to the solenoid. This electrical impulse activates a magnetic coil, lifting the solenoid's dia-
phragm plunger and opens the relief valve.
Water above the diaphragm can now flow out via the spill channel changing the pressure below the dia-
phragm. The diaphragm is now lifted from its sealing position allowing water to flow through the solenoid
valve and into the urinal inlet.
When the user leaves the reception zone the electrical signal ends allowing the plunger to drop back on
to the relief valve. Water, under mains pressure, can now refill the space above the diaphragm via the
pressure equalization hole. As the water pressure above the diaphragm increases it sinks back into the
sealing position and closes the water flow.
Fault
Solenoid valve does not shut off
Test: Remove plug from the solenoid
valve
- If water flows:
- If water does not flow:
Solenoid valve does not open
Test: Operate solenoid valve with an
external source
have the testing done by an
(
electrician)
a) 43 586 / 43 587 / 43 588: 24 V DV
b) 43 592 / 43 593 / 43 594: 230 V AC
1
Cause
• Jet (B) within the diaphragm
blocked
• Tappet (A) and sleeve
calcified
• Diaphragm defective
• Tappet spring (D) defective
• Electronic gear defective
• Pressure release hole (C)
blocked
• Coil defective
Action
- clean
- clean with anti-liming agent
or steel cotton
- exchange
- exchange
- send to supplier for checking
- clean the pressure release
holes situated within upper
and lower part
- exchange
2

Werbung

loading

Diese Anleitung auch für:

43 58743 58843 59243 59343 594