Herunterladen Inhalt Inhalt Diese Seite drucken

Intended Use Of The Product; Product Description; Technical Data; Instruction To The Owner - Hedson IRT UV SPOTCURE Bedienung- & Ersatzteile-Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 7

1. Intended use of the product

This product serves exclusively to accelerate the curing
of UV-putty, filler, base and clear coats. The product
must not be used for other purposes than the described
curing processes. The maximum ambient temperature
during operation should not exceed 40°C.
Do not use the product in spray booths or within a
distance of 5 m from other solvent based spraying
activities in order to avoid explosion risks.
It´s site of use is the preparation area and finishing
area. Within the automotive industry and vehicle repair
sectors, it is used to cure small areas before polishing.

2. Product description

The IRT UV SpotCure is equipped with four 100W LED
modules emitting UV and visible light at 375-430 nm
with its peak at 395 nm.
Use products/UV-paint systems designed for 395 nm.
UV curing
The ultraviolet light spectrum generated by a UV LED
interacts with special coating chemistries to produce a
high-quality, durable curing. In many applications, UV
curing can achieve a faster curing and therefore also at
a lower total cost. As the UV coat contains less solvent
then conventional paint, the UV SpotCure has less
environmentally impact.
Most importantly to achieve a good and fast curing result
there must be enough UV-A intensity. IRT UV radiation has
an outstanding intensity to achieve the best curing result.
Unique benefits of the UV cure coating
• Reduced amount of solvent
• Fast curing time
• Low-temperature processing
• Scratch resistant and chemical resistant

3. Technical data

Intensity (mW/cm²/nm) at 395nm.
10 cm distance
>3
≤ 6
≤ 12
Voltage
Frequency
Current
Recommended fuse
Power
Noise level
Weight total
Weight hand unit
Wavelength (peak)
Risk Group EN62471: 3 (RG-3)
IRT UV SpotCure is in excess of the Exempt Group and
viewer-related risk is depending upon the use of the
product.
4
5 cm distance
>12
≤ 24
≤ 48
220-240 V 1 ~/PE
50-60 Hz
2 A
10A
425 W
< 70 dB (A)
7 kg
1,4 kg
395 nm
Efficiency decreases outside 395 nm, according to graph
below (at 20 cm distance)
35000
30000
25000
20000
15000
10000
5000
0
300
350
Irradiance map IRT UV SpotCure
12 cm
24 cm

4. Instruction to the owner

The owner of the curing device must produce clear
operating instructions, adapted to local site conditions,
and make these available to all users.
Only original spare parts shall be used to maintain the
products high safety.
Dispose of spent items at the nearest environmental
protection facility for recycling.
The UV-radiation emission is:
according to EN62471 = Risk Group 3 (RG-3)

5. Markings

(715105) UV emitted from this product. Skin or eye
injury could result. Avoid exposure of eyes and skin to
unshielded lamp. Warning! UV RADIATION. Always wear
eye protection.
EN
400
450
Wavelength (nm)
715065 rev 4
500

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis