Please observe the following
1.3

For your Safety

Please refer also to the relevant Technical Data Sheet for the adhesive to be processed.
Download from www.loctite.com or request the Technical Data Sheet and the Safety
Data Sheet from your Henkel Technical Service.
INSTRUCTIONS given in these data sheets must be followed scrupulously at all times!
While under warranty, the unit may be repaired by an authorized Henkel service
representative only.
Danger!
Improper handling of chemicals may result in potential health hazards!
Observe general safety regulations for the handling of chemicals!
Always wear goggles when working with compressed air!
Before starting operation, check the dispensing system for visible damage and make
sure that it is operated only when in perfect working order!
Any defects found must be reported immediately! Remedy any defects immediately!
Use only original substitute and spare parts. We cannot be held responsible for damage
or injury of any kind because of failure to observe the instructions in this Operating
Manual.
1.4

Field of Application (Intended Use)

The Semi-Automatic Controller 97102 controls the exact application of LOCTITE
Products from a product reservoir by means of a dispensing valve.
It can be combined with the following LOCTITE Units to from a dispensing system:
1 Product reservoir (product tank or cartridge reservoir emptying unit with or without low
level and empty sensor).
1 Pneumatic dispensing valve.
Depending on the combination of components, it is possible to dispense the following
products:
– Anaerobic curing adhesives
– UV light curing adhesives
– Humidity curing cyanacrylate adhesives
2

Description

2.1

Theory of Operation

The Semi-Automatic Controller 97102 controls the selected dispensing pressure in the
product reservoir and the pneumatic opening of the dispensing valve according to the
selected dispensing time.
The start signal for dispensing is provided by an external Footswitch.
Error messages are shown on the digital display and are accompanied by a beeping tone
(see Section 8).
When a product reservoir is connected, the pressurization or depressurization of the
automatic reservoir is automatically controlled when the control unit is switched on or off.
When an empty signal is received, the automatic reservoir 97106 / 97108 is
automatically depressurized.
The control unit indicates that the automatic reservoir was refilled. By acknowledging this
message with button
the automatic reservoir is again pressurized.