Herunterladen Inhalt Inhalt Diese Seite drucken

Henkel Loctite 97102 Bedienungsanleitung Seite 8

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2
Description
8
9
10
11
a
11
b
12
Caution!
Removing, jumpering or putting out of operation of the safety devices can result in
damage to the unit and is therefore prohibited!
13
14
15
16
17
8
Precision Pressure Regulator
Precision regulator for adjusting the dispensing pressure.
By turning the regulator knob, the dispensing pressure is adjusted in the range
from 0.00 to 7.00 bar (0.00 to 100 psi).
If the error message „Press. 0.83 NOK" appears with beeping, the dispensing
pressure was changed more than ± 10 %. The value 0.83 [bar/psi] is only an
example for the displayed dispensing pressure (see Chapter 7).
By pressing button ENTER the indicated dispensing pressure is stored as the new
comparison value for automatic pressure monitoring. The error message and
beeping is eliminated.
Control Air Connection (Dispensing Valve), dispensing valve open.
The single pneumatic hose to the dispensing valve is connected here (for
connections, see Section 8.2).
Control Air Connection (Dispensing Valve), dispensing valve closed.
The single pneumatic hose to the dispensing valve is connected here (for
connections, see Section 8.2). If a dispensing valve is used with single-acting
actuator, this plug must be closed with a blind plug.
P in - Main air connector
2 - 10 bar (30 PSI - 145 PSI) for air hose OD Ø 6 mm
P out - Pneumatic Connection Reservoir
Regulated air pressure supply (0 - 7 bar, 0 – 100 PSI) to the reservoir, for
+ 0.05
air hose OD Ø 6 mm
–0.10
Power Fuse
Power Cord
Power Supply Socket
Footswitch (Accessory to be ordered separately!)
Signalling device for starting the dispensing sequence.
The dispensing time in time-controlled mode corresponds to the value on the
digital display and is independent of the length of time that the Footswitch is
depressed (see Section 2.3.1). In continuous mode, the product is dispensed as
long as the Footswitch is depressed (see Section 2.3.2).
Socket XS1: Start
The Footswitch 15 is connected here. A "Ready" signal is provided at Pin 3 and 4.
Socket XS2: Reservoir
The product reservoir is connected here.
, ID Ø 4 mm.
+ 0.05
, ID Ø 4 mm
–0.10