Application
Can be used in conjunction with: Pressurised storage
heaters, thermally and hydraulically controlled
instantaneous heaters. Operation with low-pressure
displacement water heaters is not possible.
Technical Data
• Flow pressure
min. 0.5 bar / recommended 1 - 5 bar
• Operating pressure
• Test pressure
If static pressure exceeds 5 bar, a pressure reducing valve
must be fitted.
Avoid major pressure differences between hot and cold
water supply.
• Flow rate at 3 bar flow pressure
32 306
32 307
• Temperature
Hot water inlet:
Recommended:
Scalding protection possible by fitting a temperature
limiter (see replacement parts fold-out page I,
order no.: 46 308)
• Water connection
Installation
Flush pipes thoroughly.
Install S-unions and fit mixer, for required dimensions,
see fold-out page II, Fig. [1].
1. Install the S-unions and sleeve, preassembled with the
escutcheon.
2. Screw-mount the mixer.
3. Push the sleeve with escutcheon onto the union nut.
4. Screw the escutcheon flush against the wall.
Refer to the dimensional drawing on fold-out page I.
The cold water supply must be connected on the right and
the hot water supply on the left.
The projection can be increased by 30mm with an
extension, (see replacement parts fold-out page I,
ref. No. 46 238).
Open cold and hot-water supply and check
connections for leakage.
Check mixer operation, see Fig. [2].
max. 10 bar
16 bar
approx. 20 l/min
approx. 17,5 l/min
max. 80 °C
(energy saving) 60 °C
cold - right
hot - left
Function of automatic diverter (A), see Fig. [3].
Pulling the lever will release water delivery.
Water will emerge from the bath outlet first.
Press diverter knob = to divert flow from bath inlet
Pull diverter button
= to divert flow from shower outlet
Flow is diverted automatically from shower outlet to bath
inlet when the mixer is turned off.
Flow rate limiter
This mixer is fitted with an adjustable flow rate limiter,
permitting an infinitely variable individual reduction in flow
rate. The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combination with
hydraulic instantaneous water heaters is not
recommended.
To activate, see "Replacing the cartridge" steps 1 to 3,
Figs. [4] and [5].
Maintenance
Inspect and clean all parts, replace as necessary and
grease with Grohe special grease (order no. 18 012).
Shut off cold and hot water supply.
I. Replacing the cartridge, see Fig. [4].
1. Lever out plug (B).
2. Loosen set screw (C) with 3mm socket spanner and
remove lever (D).
3. Remove cap (E).
4. Remove screws (F) and detach complete cartridge (G).
5. Replace either complete cartridge (G) or seals (G1).
Assemble in reverse order.
Observe the correct installation position.
Ensure that the cartridge seals (G1) engage in the
grooves on the housing. Fit screws (F) and tighten evenly
and alternately.
II. Diverter, see Fig. [6], [7] and [8].
1. Raise diverter button (H) and lever out diverter knob (J)
with a screwdriver, see Fig. [6].
2. Screw out nut (K) by countering diverter plate (L) and
remove the remaining components (M), see Fig. [7]
and [8].
3. Unscrew diverter (N), see Fig. [8].
III.Remove non-return valve (08 565), see fold-out
page I.
IV.Unscrew and clean aerator (13 927), see fold-out
page I.
Assemble in reverse order.
Replacement parts, see fold-out page I
( * = special accessories).
Care
For directions on the care of this fitting, please refer to the
accompanying Care Instructions.