TECHNICAL DATA

MODEL
TYP
OUTPUT
max.
(1)
min.
FUEL
Gas pressure at maximum delivery.
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATUR
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
FAN MOTOR
(star-delta starting for RS400 and RS500)
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
CONFORMITY TO EEC DIRECTIVES
NOISE LEVELS
(3)
APPROVAL
Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(1)
Pressure at pressure switch test point 20)(A)p.12 with zero pressure in the combustion chamber and maximum burner output.
(2)
Sound pressure measured in manufacturer»s combustion laboratory, with burner operating on test boiler and at maximum rated output.
(3)

ACCESSORIES

(optional)
KIT FOR MODULATING OPERATION
Output power regulator kit RWF40
There are two components to order:
• the Output power regulator to install on the burner;
• the Probe to install on the heat generator
Parameter to control
Adjustment field
Temperature
- 100...+500°C
Pressure
0...2.5 bar
0...16 bar
• UV CELL KIT
• KIT INTERFACE ADAPTER RMG TO PC
• POTENTIOMETER KIT FOR THE INDICATION OF LOAD POSITION
GAS TRAIN ACCORDING TO REGULATION EN 676
Note.
Riello S.p.a. declines all responsibility for the addition of safety devices not provided for herein.
kW
kW
Gas: G20/G25
mbar
(2)
°C
°C max
rpm
V
kW
A
V1 - V2
I1 - I2
kW max
dBA
class 3 (EN 676)
CE
Probe
Type
Code
3010110
PT 100
3010213
Probe with outlet
3010214
4...20 mA
RS 300/M BLU
859 T
1350 ... 3800
500
NATURAL GAS: G20 (methane) - G21 - G22 - G23 - G25
18 / 26
Intermittent
Boilers: water, steam, diathermic oil
0 - 40
60
3N ~ 400 / 230V +/-10% 50 Hz
2900
230/400
4,5
15,8 - 9,1
6
IP 54
98/37 - 90/396 - 89/336 - 73/23
82
Output power regulator
Type
Code
3010356
RWF40 BASIC
3010357
RWF40 HIGH
code 3010359
code 3002719
code 3010402
: see page 23.
8
RS 400/M BLU
RS 500/M BLU
860 T
1800 ... 4500
2500 ... 5170
800
33.4 / 38.7
38,2 / 55,8
2900
400/680
7,5
16 - 9
18 - 10,5
230 V - 1 x 8 kV
1 A - 20 mA
9
85
Output power regulator with signal
4-20 mA, 0-10V
There are two components to order:
• the Analogic signal converter;
• the Potentiometer
Analogic signal
Potentiometer
Type
Code
Type
3010402
ASZ...
E5202
856 T
1000
2900
400/680
9,2
11
88
converter
Code
3010390