Herunterladen Inhalt Inhalt Diese Seite drucken

General Information; Functional Description; Storage And Transportation Conditions - Metasys Meta Air 24S Einbau, Betrieb Und Wartung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

META Air 24s / 24 / 30
Chapter 1 - 8
1.
Index
Chapter
1.
Index
2.
Explanation of the pictograms
3.

General information

4.
Application
5.
Scope of delivery
6.
Explanation of the type plate
7.

Functional description

EN
8.

Storage and transportation conditions

9.
Installation guidelines
10. Instrument unit
11.
Electrical connections
12. Preparation before first use
13. Commissioning and usage
14. Wiring diagram
15. Service and maintenance
16. Decommissioning and disposal
17.
Troubleshooting
2.
Explanation of the pictograms
i
Information
Caution!
General warning sign
3.
General information
The safety, reliability and performance of the appliance is
only guaranteed by METASYS if the following instructions
are observed:
ƒ Assembly, alterations or repairs may exclusively be carried out by
authorized service personnel in compliance with medical devices
guideline 93/42/EEC.
ƒ The electrical installation must comply with the regulations of the
IEC (International Commission for Electrical Engineering).
ƒ The apparatus must exclusively be used in conformity with the
instructions for installation, operation and maintenance.
ƒ Only original parts may be used for repairs or replacements.
ƒ Following the commissioning of the apparatus, the Installation
Proof must be completed and returned to METASYS to establish the
guarantee period.
ƒ Every service and inspection must be recorded in the Equipment
Logbook.
ƒ When requested by an authorized engineer, METASYS agrees to
10
make all documents available for the use of technically qualified
service personnel.
ƒ METASYS accepts no responsibility for damages caused due to
Page
external factors, such as wrong installation, improper use of the
10
apparatus or unauthorized technical intervention.
10
ƒ Users must study equipment and assure themselves of its good
10
condition before every use.
10
ƒ When the whole compressor is dismantled at the end of its service
10
life, it must be disposed of properly.
10
10
4. Application
10
METASYS META Air compressors produce oil-free, filtered compressed
11
air required for the operation of dental units or similar applications.
11
The compressors are designed for operation in dry
11
ventilated rooms and may therefore not be operated in a
11
damp or wet environment!
12
12
Use of the compressors in the vicinity of gases or
12
inflammable liquids is also prohibited.
13
13
5.
Scope of delivery
All METASYS META Air compressors are shipped in a single package
consisting of a pallet plus carton. A booklet containing the installation
proof, equipment logbook and manual for installation, operation and
maintenance is included in each shipment.
6. Explanation of the type plate
1
Picture
: The type plate is located on the fitting panel.
Equipment type
1.1
Mains supply data
1.2
Serial number
1.3
Address of the manufacturer
1.4
CE marking
1.5
Protection class I
1.6
7.
Functional description
The compressor power unit sucks in air from the outside through the air
intake filter. The air is compressed in an oil-free compression chamber,
then passes through a delivery hose and is forced through the non-
return valve into the pressure tank. The air flow is regulated by a valve
plate that allows air flow in one direction only.
8. Storage and transportation conditions
During transportation the compressor must be protected from moisture,
dirt and extreme temperatures. The packaged compressors must be
stored in a dry place (max. relative air humidity 70%) at a storage
temperature of -10°C to +40°C.
Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Meta air 24Meta air 30

Inhaltsverzeichnis