Table 1: Operating malfunctions
Problem
Gas odour
EN
Burner does not turn on
Burner does not stay on

GAS CONNECTION

– All the gas connection, transformation and pressure control operations must be per-
formed by authorised personnel who must have specific technical skills and special abil-
ities in the specific sector. This also applies for all extraordinary maintenance operations
such as lubrication and/or faucet replacement and thermocouple or burner replacement.
– Equip the appliance gas supply tube with a faucet to be able to cut of gas supply in the
event of need.
Causes
Temporary leak when flame is
extinguished.
The piezoelectric switch does
not work
The thermocouple is not
sufficiently heated
- 18 -
Solutions
Close the supply faucet and
ventilate the room
Check piezoelectric switch
efficiency and, if necessary,
manually ignite with a free
flame
If the problem persists, contact
your dealer or authorised
service centre
Insist with the ignition operation
longer