T R O U B L E S H O OT I N G
T R O U B L E
If your refrigerator or freezer is not operating
properly, use the following troubleshooting
guide before calling your Sub-Zero dealer or
regional distributor. This guide will save you
time and trouble and may avoid the expense
of a service call.
SERVICE is illuminated in the exterior
temperature display
SERVICE is flashing in the exterior
temperature display
18
S H O O T I N G
The microprocessor has sensed a
problem with the operating system. There
may be instructions in the exterior
temperature display to solve the problem.
If not, call your Sub-Zero dealer or
regional distributor for assistance.
This happens when one or more of the
zones runs too long, or a temperature
sensor may be faulty. This could be from
a dirty condenser. If this occurs, clean the
condenser following the procedure
outlined on page 15. Turn the unit off
with the POWER
key pad and then
restart by depressing the key pad again.
If SERVICE is still flashing, call your
Sub-Zero dealer or regional distributor for
assistance.
G U I D E
Service and ice lights are both flashing
Refrigerator/Freezer is not running
Refrigerator/Freezer is warmer than usual
This occurs when the solenoid valve for
the ice maker is activated too long. Check
for excess water near the ice maker. If
you see excess water, turn off the water
at the shut-off valve and call for service. If
there is no excess water, turn the unit off
and back on to reset and see if this
corrects the problem. If the problem
continues, call your Sub-Zero dealer or
regional distributor for assistance.
Is there electrical power to the unit?
Is your home circuit breaker or fuse off?
Is your refrigerator/freezer control set to
"ON"?
Is the condenser area clean?
Has either door been left open for an
extended period? Be sure that food is not
obstructing proper door or drawer
closing.
If unit has been off for short time frame
and unit is still not running, it may be in
defrost mode.
Wait 30 minutes and try to restart again.
Is your control set properly?
Is your condenser area clean?
Has the door been open for a long time?
Have you recently added a large amount
of food?