Herunterladen Diese Seite drucken

How To Connect Remote Controller For Wire Operation - Toshiba RAS-18N3KV2-E1 Installationsanleitung

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 46
CAUTION
• Be sure to refer to the wiring system diagram labeled inside the front
panel.
• Check local electrical cords and also any specifi c wiring instructions or
limitations.
Cord clamp
Screw
Terminal cover
Screw
Connecting cable
Stripping length of the connecting cable
NOTE
• Use stranded wire only.
• Wire type : More than 1.5 mm² (H07RN-F or 60245 IEC66) or 1.3 mm²
(AWG-16)
How to Connect Remote Controller
for Wire Operation
CAUTION
• Be sure to install control wire along
the wall so that there is no slack and
fi x remote controller on the wall.
For indoor unit
1. Open the air inlet grille upward.
2. Securely remove four screws at the front panel.
3. Slightly open the lower part of the front panel then pull the upper part of
the front panel toward you to remove it from the rear plate as shown on
fi gure 1.
4. After removing the front panel, remove the screws and Display unit from
the unit as shown on fi gure 2 then open the front cover of Display unit
as shown on fi gure 3.
5. Arrange the control wire as detail and specifi cation as shown on fi gure 4.
6. Securely connect the control wire to terminal of Display unit board as
shown on fi gure 5 (tighten fi rmly but not over 0.12 N·m (0.01 kgf·m)).
7. Set the control wire throughout at slot on front cover of Display unit then
reassembly Display with main casing by reverse process of fi gure 2 and
3. Make sure the control wire must not be pressed by front and rear
cover of Display unit.
8. Set the control wire out from indoor unit same portion as power supply
and connecting cable as shown on fi gure 6.
9. Reassembly the indoor unit by reverse process of 1 to 3.
Air inlet grille
2
Terminal block
Earth line
Connecting cable
110 mm
Earth line
20 mm
10 mm
80 mm
Indoor unit
Control wire
Remote controller
1
Front panel
3
1
* Wire size 28-22 AWG (0.08-0.32 mm
2
)
Outer diameter not over 4.7 mm, control wire
length less than 30 m.
5
Tighten fi rmly but
Terminal
not over 0.12 N·m
Control wire
(0.01 kgf·m)
For remote controller
1. Remove cover of remote controller by sliding down and take it out.
2. If batteries are exist, please take them out. The combination of using
wire controller and batteries may cause of batteries explosion.
3. Make hole for insert control wire by use screwdriver break the polyester
sheet as shown on fi gure 7.
4. Insert control wire from rear side of remote controller as shown on
fi gure 8.
5. Fix control wire which arrange as shown on fi gure 9 and ! to terminal
by provided screws (tighten fi rmly but not over 0.25 N·m (0.03 kgf·m)).
6. Set control wire through gutter way at rear side of remote controller as
shown on fi gure ".
7. Fix provided screw (Ø3.1×16L) on the wall to hang remote controller as
shown on fi gure #.
8. Mark and arrange hole for fi x below screw (Ø3.1×25L) as shown on
fi gure #.
9. Assembly battery cover which provided with accessory bag then use
provide screw (Ø3.1×25L) to fi x battery cover together with wall as
shown on fi gure $ (tighten fi rmly but not over 0.15 N·m (0.02 kgf·m)).
10. Reassembly cover of remote controller.
7
Polyester sheet
close hole for insert
control wire
30 mm
9
10 mm
* Wire size 28-22 AWG (0.08-0.32 mm
Outer diameter not over 4.7 mm,
control wire length less than 30 m.
5
2
Remove screw
Display unit
70 mm
4
5 mm
Control wire out position
Control wire through out position
2
)
Control wire
Terminal
Tighten fi rmly but not over
0.25 N·m (0.03 kgf·m)
3
EN
ES
Display board
FR
IT
DE
6
PT
Control wire
PL
CZ
RU
CR
HU
TR
NL
GR
SV
FI
8
NO
DK
Control wire
RO
!
BG
EE
LV
SK
SI

Werbung

loading

Diese Anleitung auch für:

Ras-b22n3kv2-e1Ras-18n3av2-eRas-22n3av2-e