FM Flow meter (partial demineralisation)

A throughflow monitor  measures the amount of processed water
and displays this in the FM flow meter .
If the set amount is exceeded, or if there is a fault, an optical LED
lights up  and an acoustic signal is given.
If the demineralisation cartridge is depleted it must be replaced with a
new one and the spent resin sent away for reprocessing.
– TE P 2000 and TE P 2800 cartridges:
Send cartridges filled with spent resin away for reprocessing.
– LP 2800 cartridge:
Replace the resin. The E 316 Resin replacement set is supplied with
its own instruction manual.