Installation
- Plaster and tile the wall, excluding the area occupied
by the mounting template. Seal any apertures in the
wall so that they are watertight to spray water.
• Tiles laid in mortar should be pointed so that the
joint is tapered towards the outside.
• Seal prefabricated walls with a permanently
plastic compound.
- Remove the mounting template, see fold-out page I
fig. [1].
- Fit sleeve (C), see fig. [2].
- Grease the seal (D) for the escutcheon mounting
bracket (E) with the special grease supplied and
install escutcheon mounting bracket (E) with
screws (F), see fig. [3].
- Fit the escutcheon (G).
If the thermostat has been installed at too great a
depth, this can be adjusted by 27.5mm with an
extension set (see fold-out page II, ref. No. 47 653).
Adjustment
Installation of the thermostat knob and
temperature adjustment, see figs. [4] and [5].
• Before the mixer is put into service if the mixed
water temperature measured at the point of
discharge varies from the specified temperature set
on the thermostat.
• After any maintenance operation on the
thermoelement.
1. Open the shutt-off valve and check the temperature
of the water with a thermometer, see fig. [4].
2. Turn the adjusting nut (Q) clockwise or anticlockwise
until the water temperature reaches 38 °C.
3. Install temperature control handle (H) in such a way
that the 38° mark is at top, see fig. [5].
4. Fit snap insert (J) and install with screw (K).
5. Fit knob (L).
Reversed union (hot on right - cold on left).
Replace thermoelement (M) or (N), see replacement
parts fold-out page II, ref. No.: 47 657 (1/2")
and 47 658 (3/4").

Temperature limitation

The safety stop limits the temperature range to 38 °C.
If a higher temperature is desired, the 38 °C limit can
be overridden by depressing the button (H1).
Prevention of frost damage
When the domestic water system is drained,
thermostat mixers must be drained separately, since
non-return valves are installed in the hot and cold
water connections.
The complete thermostat assemblies and non-return
valves must be unscrewed and removed.

Maintenance

For maintenance, see fold-out page II and fig. [6].
Inspect and clean all parts, replace if necessary and
grease with special valve grease.
Shut off cold and hot water supplies.
I.Thermoelement
1. Pull off knob (L).
2. Unscrew screw (K) and pull off snap insert (J).
3. Pull off temperature control handle (H).
4. Remove clip (A).
5. Pull off stop ring (B).
6. Remove adjusting nut (Q) with overload unit (Q1).
7. With a 22mm open-ended spanner, unscrew and
remove thermoelement (M) or (N).
Readjustment is necessary after every maintenance
operation on the thermoelement (see Adjustment).
II. Non-return valve
1. Pull off knob (L).
2. Unscrew screw (K) and pull off snap insert (J).
3. Pull off temperature control handle (H).
4. Detach escutcheon (G) in accordance with fig. [6].
5. Remove screws (F) and escutcheon mounting
bracket (E).
6. Unscrew non-return valve (O) or (P) with 17mm
socket wrench or 10mm socket spanner.
7. Remove non-return valve (P1) and filter (P2).
Reassemble in reverse order.
Observe the correct mounting position!
Replacement parts, see fold-out page II ( * = special
accessories).
Care
For directions on the care of this fitting refer to the
accompanying Care Instructions.