WARNING!!
DO NOT spray the oven with a water jet.
DAILY
1. Saturate a cloth with light oil. Wipe the oven exterior
when it is cold. Dry the oven with a clean cloth.
2. Clean stainless surfaces with a non-toxic industrial
stainless steel cleaner. Apply the cleaner when the
oven is cold, and always rub with the grain of the
metal.
3. Clean the porcelain interior with a non-toxic industrial
porcelain cleaner.
WEEKLY
1. Remove the racks and rack support. Soak them in a
solution of ammonia and water.
2. Clean the air intakes on a weekly basis. Air intakes
provide necessary cooling air to the internal compo-
nents. They are generally located on the rear and
sides of the equipment.
EVERY 12 MONTHS
For all oven models:
1. Check the main electrical connection
2. Remove the blower whel. Soak in a solution of am-
monia and water.
For gas models only:
1. Check the venting system for possible deterioration
Blower Wheel Cover
resulting from moisutre and corrosive flue products.
2. Check and adjust the gas setting.
For parts and service contact your distributor:
Middleby UK LTD
4 Cranford Court
Hardwick Grange, Woolston
Warrington, WA1 4RX
England
44-1925-821280
44-1925-815653
44-1925-815653
Middleby France
Sebas Fernandez
+34 94 454 28 15
sfernandez@middleby.com
Middleby Germany
Arjan Koole
+49 7191 733085
akoole@middleby.com
Middleby Spain
Alvaro de la Torre
+34 94 454 2815
+34 94 454 0257
+34 94 454 0257
adelatorre@middleby.com
You may also contact Blodgett Technical Service at (802)
658-6600 or visit www.blodgett.com.
Blower Wheel
DFG-100-ES shown
Figure 13
13

Maintenance

Cleaning

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis