Herunterladen Diese Seite drucken

Teleco TVHET868A02 Handbuch Seite 10

230-volt-funkempfänger

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

14 - To delete a transmitter from transmitter
1- Press three times the
button P3 placed inside of the
transmitter. Buzzer will sound
intermittently and slowly.
WARNING
The above mentioned product must be installed only by qualified technical personnel in
compliance with the standards. All connections must be rated for a single-phase power supply
of 230V. For the disconnection from the power line, use an all-pole switch with contact with
an opening of at least 3,5mm. Only suitable materials for the connections must be used to
guarantee insulation that complies with current standards on the subject of electrical safety.
The appliance has been tested with a power supply wire type H05VV-F; the power supply wires for
outdoor use have not to be lighter than the ordinary wires type H05RN-F.
The programmer is in conformity with the RAEE and RoHS directive.
The installation of the control unit has to be done by fixing the box vertically with the clamps
downwards.
The earth wire must be longer than the other wires because it must be the last to break off if
the cable clamps are slack.
The heat sink placed on the box with maximum load of 2000W can arrive at a temperature of
65°C.
In the view of a constant development of their products, the manufacturer reserves the right for
changing technical data and features without prior notice.
P3
2- During the intermittent sound press the
push button which is to be deleted; the
deletion is indicated by the continuously
sound of the buzzer.
10

Werbung

loading