Herunterladen Inhalt Inhalt Diese Seite drucken

F4: M; F3: E Rrors; F2: P Rogram - SUHNER MACHINING GEM 12 Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6

3.1.2 f4: m

echAnicAl configurAtion
To select the spindle configuration, enter its number. The
selected configuration must agree with the mechanical
configuration (see operating instructions no. 30004926
GEM 12 for the setup) (1). Enter the number of teeth on
the belt pulley for the pitch (2). The pitch calculated from
(2) appears (3). Select the system of units (4). When the
self test is activated, the first startup after a change ex-
amines during the first cycle whether the entered values
correspond to the installed configurations (5).
3.1.3 f3: e
rrors
1
2
Display error (1). Corresponding error number (2).
3.1.4 f2: p
rogrAm
From left to right: Rapid traverse speed (rpm) / Start of
2
1
3
4
5
1
working speed (mm) / Working speed (rpm) / Reversal
point (mm) / Dwell time (s) (1)
From left to right: Zero point displacement (mm) / Rapid
traverse speed on return stroke (rpm) / Staart of rapid
traverse speed on return stroke (mm) / Working speed on
advance (rpm) (2).
All measurements are absolute (calculated from
the zero point).
3.1.5 f1: c
onfigurAtion
Current position of the spindle (1). Current speed (2). Re-
quired speed based on the asynchronous motor's rated
power (3).
Current output signals from the controller, 1=active, 0=in-
active (4).
2
1
2
3
4
15

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für SUHNER MACHINING GEM 12