Herunterladen Inhalt Inhalt Diese Seite drucken

König+Neurath TALO.S Bedienungs- Und Montageanleitung Seite 64

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Error messages on the handswitch display
The display reads HOT.
Cause
The control unit is fitted with over-
heating protection. Overheating has
caused it to stop the control unit.
The display reads E + an error code.
Cause
There is an internal fault in the
control unit.
No.
Description
00
Internal error channel 1
01
Internal error channel 2
02
Internal error channel 3
12
Defect channel 1
13
Defect channel 2
14
Defect channel 3
24
Overcurrent motor M1
25
Overcurrent motor M2
26
Overcurrent motor M3
48
Overcurrent motor group 1
49
Overcurrent motor group 2
60
Collision protection
62
Overcurrent control unit
Remedy
Wait until the control unit has
cooled down and HOT is no longer
displayed. The control unit is then
operational again.
Remedy
Proceed as indicated in the
following error list.
Remedy
Unplug power cord and
contact the customer service.
Unplug the control unit.
Fix the external short circuit or
plug in the correct motor to the
motor socket that shows the error.
Start the control unit again.
Remove jammed objects from the
driving area.
Desk might be overloaded
remove load from desktop.
Contact customer service.