Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions - HANSGROHE Metris Puro 31461000 Gebrauchsanleitung, Montageanleitung

Vorschau ausblenden Andere Handbücher für Metris Puro 31461000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Safety Notes
Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Connections:
Recommended hot water temp.:
Thermal disinfection:
• The product is exclusively designed for drinking water!
• Safety against backflow
Fault
Insufficient water
Mixer stiff
Mixer dripping
Instantaneous heater didn't work
Hot water temperature too low
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 70°C
cold right - hot left
65°C
max. 70°C / 4 min
Cause
- check valve hasn't moved back
- Cartridge defective, calcified
- Cartridge defective
- Flow limiter in handshower isn't
removed
- Filters are dirty
- check valve hasn't moved back
- Hot water limiter incorrectly set
Assembly see page 11
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 14)
To adjust the hot water limiter. Using a hot
water limiter in combination with a continu-
ous flow water heater is not recommended.
Dimensions (see page 16)
Flow diagram (see page 16)
Operation (see page 15)
Hansgrohe recommends not to use as drink-
ing water the first half liter of water drawn
in the morning or after a prolonged period
of non-use.
Cleaning (see page 21)
Spare parts (see page 18)
Test certificate (see page 18)
Remedy
- Exchange check valves
- Exchange cartridge
- Exchange cartridge
- Remove flow limiter
- Clean filters
- Exchange check valves
- Set hot water limiter

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis