Applications
Only suitable for vertical installation in cistern GD2.
Cistern A: Produced from 06.2007 with outlet valve,
item no. 42 320.
Cistern B: Produced up to 05.2007 with outlet valve,
item no. 42 253.
6-litre cistern: Produced from 06.2008

Safety notes

• Installation is only possible in frost-free rooms.
• The control electronics are only suitable for indoor use.
• In the case of damage to the external transformer
connection cable, this must be replaced by a qualified
electrician in order to prevent a hazard.
• The 230 V AC supply must not be fed into the cistern and
the transformer must not be installed in the cistern.

Technical Data

• Supply voltage
(transformer 230 V AC/12 V AC)
• Power consumption
• Reception range according to Kodak Gray Card,
grey side, 8x10", landscape (factory setting):
• Flow volume
- Pre-flush
3 l (factory setting: deactivated)
- Main flush
3 - 6/9 l, adjustable
(factory setting: 6l)
• Intermediate flush
Every 60 min (max. 3x)
(factory setting: activated)
• Automatic flush
72 hours
(factory setting: activated)
• Type of protection
- Fitting
- Transformer
Electrical test data
• Software class
• Contamination class
• Rated surge voltage
• Temperature for ball impact test
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
5
Special accessory (infrared remote control 36 206)
• With the infrared remote control (Prod. no.: 36 206), the
following settings can be made and changed:
• Set detection zone (30 - 80cm)
• Set flush duration (flow volume (3 - 6/9 l)
• Trigger flushing
• Switch off fitting
• Restore basic setting
• Test mode = waterless simulation
• Switch on/off 72-hour flush
• Switch on/off intermediate flush
• Switch on/off pre-flush
• Set minimum delay time

Operation

The infrared electronic system emits invisible pulsed light.
The infrared-electronics are adjusted so that the outlet valve is
actuated when a person moves out of the detection zone after
the minimum delay time has elapsed. The water flow starts
and the WC is flushed.
The detection range is dependent upon the reflective
properties of the object.
Installation
230 V AC
A vacant tube (B) is required for the line between
transformer (A) and electronics (C), see fold-out page II,
4 VA
Fig. [2].
Plaster and tile the wall, excluding the area of the structural
72cm
shell protection.
Electrical installation
Electrical installation work must only be
performed by a qualified electrician. This work
must be carried out in accordance with the
regulations according to IEC 364-7-701-1984
(corresponding to VDE 0100 Part 701) as well as
all national and local regulations.
IP 59K
IP 55
• Only water-resistant round cables with max. outside
diameter 6.0 to 8.5mm may be used.
• The voltage supply must be separately switchable.
A
2
1. Fasten base (A1) of transformer using screws (D),
2500 V
see Fig. [3]. Drill holes first if necessary.
100 °C
2. Insert 230V connecting cable (E) into the base.
Strip insulation in accordance with Fig. [3].
3. Pull sleeve (F1) over the two current-carrying wires (E1).
4. Attach lustre terminal (F); observe assignment, see
Fig. [4].
5. Secure all three wires with the cable tie (F2), just in front
of the lustre terminal (F).
6. Route strand (E1) in an arc and position lustre terminal (F)
on locators in base (A1), see Fig. [5].
7. Secure cable (E) using screws (H) and strain relief (G).
8. Fasten cover (I) in base (A1) using screw (J).
9. Attach upper part (A2) of transformer.
10. Cut off structural shell protection as flush as possible with
the tile surface, see Fig. [6].
11. Feed extension cable (L) through vacant tube (B) into the
cistern and connect to transformer (A), see Fig. [7].