Herunterladen Inhalt Inhalt Diese Seite drucken

Modes Of Operation - elv 124857 Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 5
PIR
MOTION DETEC
EN
Recess
mounted in round
The passive infrared motion
detector
controller capable of controlling a lighting system (see controllable power in technical specifications table).
During the night or in the dark, the motion
During the day or in environments with sufficient natural light, the built-in light sensor helps save electricity by deactivating the lights. Twilight
adjustment (
LUX
) sets the brightness level at which the lighting system must come into operation. An adjustable timer (
long the light stays on after activation.
« verride»
O
option
in order to keep the light on 5 h disabling the IR sensor's action
One important feature of the PIR
the load, increasing the life time of the relay.
Technical data
Power Requirement
Relay command with ZERO CROSSING
Controllable maximum power:
1000W
480W
(12 x 36W)
IP 40
Protection Degree
Maximum wire section at terminals
0,75........2,5 mm
Pollution rating
normal
Protection Class
class II
round height from the floor
Recess
mounted in a
recessed
wall box
(recommended) 1,5 ÷ 2,0 m
Detection Angle
at a distance of 3 m up to 180° at 20 °C
at a distance of 12 m up to 160° at 20 °C
Detection Distance
approx. 12 m at 20 °C
Time Adjustment
Lux Adjustment
Warm Up Time:
from 1st switch-on
or return after black-out
Indicator LED on
Operating methods
Operating Temperature
from 0 °C to +40 °C
Storing temperature
from -20 °C to +60 °C
CE marking reference standard
INITIAL OPERATION (TESTING AND ADJUSTMENT)
Turn the Time control (
TIME
) and the Light lux control (
•Switch on power (example with the wall switch).
The attached device (example Lamp)
•Walk through the detection area, the light turns on when you move and turns off with a time delay, when you stop.
TIME ADJUSTMENT (TIME): the (
Adjust the
TIME
control knob clockwise to increase (up to about 30 minutes) how long the light stays on or anti-clockwise to decrease (down to
about 15 seconds the time delay). FIG. 4A.
LIGHTING ADJUSTMENT (Lux)
detects motion. Provisionally turn the
sensor remains inactive during daylight.
At dusk
, when you find the lux orient them level desired for operation, turn the
position (lamp/lamps switch on).

MODES OF OPERATION:

Automatic operation: w
hen the sensor detects motion, the lamp connected to it lights up automatically if the ambient brightness is lower than
the brightness level set with the
LUX
trigger" mode; if, during time adjustment, the PIR sensor detects more movement, the count will reset and the timer will restart.
Manual override: to keep the lamp connected to the sensor on irrespective of motion it is possible
switch off and on
SW1 Fig. 2
(
) twice within 4 seconds (the interval between the first and second operation must be within 0,5 - 2 seconds).
In MANUAL OVERRIDE mode, the light will remain on for around 5 hours despite no motion, then the light will turn off and the Light control will
be back to Auto mode automatically. User can also set the motion sensor back to Auto operation (before 5 hours elapse) by turning off the wall
switch
SW1
for at least 10 seconds and then turn it back on.
TOR WITH
160°
wall
box
(PIR)
for recess mounting
detector
switches on the connected lighting system when it detects motion within its detection range.
detector
is the intelligent command of the "zero crossing" relay which optimises the activation and deactivation of
230 V ~
±
10%
50 Hz
250W
7W ÷ 23W
(6 x 36W tot. 30 µF)
(max. 8 lamp.)
²
from about 15 seconds to about 30 minutes
from about 20 to about 300 LUX
about 1 minute
red
AUTO
MATIC MANUAL OVERRIDE
/
LVD/EMC EN60669-2-1
LUX counterclockwise
)
lights up for approx. 1 minute (Warm up)
TIME
) adjustment controls how long the lamp will stay on after motion has been detected.
FIG. 4B LUX adjustment sets the brightness level at which the lighting system must come into operation when it
:
LUX
control knob to the edge clockwise at the moon
control knob and it stays on for the time pre-set with the
ANGLE
(see also figures on page 1)
in a round
wall
box
for indoor environments (IP40) is a fully automatic light
.
WARNINGS
Read this manual carefully before using the product as it provides important guidelines
regarding safety, installation and use. The manual must be preserved with care for future
reference.
The manufacturer reserves the right to introduce any technical and/or constructive changes deemed
necessary, with no prior notice.
Important: installation and electrical connections of devices and
appliances must be carried out by skilled people and in
compliance with current regulations.
The motion sensor is designed to be
box and is suitable for indoor use for example in condominium stairs, see fig.
6. Installation is not recommended on the ceiling.
•Make sure the 230V mains power supply is disconnected before
installing or carrying out any maintenance operations.
•Keep the detector at least 1 meter away from the controlled lighting (e.g.
Lamp) and do not position the PIR sensor toward direct sunlight.
•Do not install the sensor toward reflective surfaces (e.g. pools) or toward
heating vents, air conditioners or other devices which can rapidly vary the
temperature, causing unwanted sensor operation. Do not place any
obstacles between the sensor and the relative volumetric coverage area
(plants, shrubs, etc.).
• Prior to mounting, keep in mind that the motion sensor is
the motion, which is across the detection field and
motion, which moves directly towards the detector.
Not :
e
the
S 1
W
wall switch enables
details, consult the paragraphs regarding operating methods and
the wiring connection diagram in fig. 2.
Remove the terminal cover cap
screwdriver.
Proceed
relay/terminals unit and
recess
Reassemble the terminal cover cap. Insert the detection unit into
the relay/terminal unit, as shown in
to the edge the
TEST position
and then switches off.
position. In this provisional setting mode, the Motion
LUX
control knob in the opposite direction in the most suitable
TIME
TIME
) lets you select how
wall mounted in a round
recessed wall
more sensitive
less sensitive
override exclusion
. For further
(Fig. 2)
by using a small
with
electrical
connections
it into the round box.
Fig. 3
.
see in FIG. 4
(TEST MODE)
control knob. Note: the sensor works in "Re-
to turn off automatic operation
: turn the wall
to
to the
of
the
.
3

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis