USER DELETION PROCEDURE

1
TO DELETE A USER'S FINGERPRINT, FIRST BUTTON 2 ON
THE CONTROL UNIT SHOULD BE PRESSED.
The blue LED will start blinking slowly.
2
ADMINISTRATOR FINGERPRINT IS VERIFIED FIRST.
For security reasons an admnistrator fingerprint is needed to start
the user deletion procedure. When the administrator's finger will
be recognized, the green LED will flash, accompanied by a beep.
If a non-administrative finger will be placed on the sensor,
the device will not react and the blue LED will keep
flashing.
3
1x
GREEN AND RED LEDS WILL FLASH ALTERNATELY.
THE FINGER THAT NEEDS TO BE DELETED SHOULD
BE PLACED ON THE SENSOR.
Successful deletion will be confirmed by 3 flashes of the
orange LED, accompanied by three beeps.
If a non-stored fingerprint will be placed on the sensor, the
device will not react. Green and red LEDs will keep flashing.
1
THE PROTECTION SCREW NEXT TO THE R SIGN ON
THE CONTROL UNIT SHOULD BE UNSCREWED FIRST
AND THEN THE R BUTTON SHOULD BE HELD FOR 10
SECONDS. AFTER THIS PERIOD VIOLET LED WILL FLASH
5 TIMES AND 5 BEEPS WILL BE HEARD.
All fingerprints will be deleted from the database and the
device will have the factory settings restored.

FACTORY RESET

EN
BLUE
A
GREEN
1x
BLUE
GREEN
RED
U
ORANGE
3x
VIOLET
5x