Tone:
When the tone is switched on, the tester beeps with every fence pulse.
Switching the Tone on or off:
1.
Remove the tester from the fence until no pulse is shown.
2.
Hold the button (6) down for 10 until the beep.
3.
Release the button (6).
4.
The tone is now deactivated or activated.
Battery:
If the battery symbol flashes then the 9V battery must be replaced.
Using the tester on the fence:
1.
Start close to where the fence connection cable is connected to the fence.
2.
Test the fence system here
3.
Repeat the test approx. every 50m. (follow the flashing arrow)
If the current strength displayed decreases slowly, you are approaching the leakage.
If the current strength is considerably lower than the previous reading then you have
passed the leakage.
Exceptionally high current values mean a short circuit in the fence system, whilst
lower values tend to indicate a poor contact or breakages in the long fences.
Once you have used the tester a few of times you will get a feel for your
electric fence system!