4 kanal empfanger 433/868
Vorschau ausblenden Andere Handbücher für SEL2641R433C4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

7 - RELAYS OPERATING MODE SETTING
The relays can be programmed in 3 different modes: Impulsive (pre-planned), Bistabile (or step), Delayed. For each of
these possibilities it is possible besides to plan the range reduction function that decreases the sensitivity of the
receiver, preventing the receipt from great distance.
The configuration of each relay is displayed by the lighting of the corresponding led:
- DL1 points out that the relay is planned in impulsive mode;
- DL2 points out that the relay is planned in bistabile mode ;
- DL3 points out that the relay is planned in delayed mode;
- Besides DL4 points out that for the relay the range reduction has been activated.
While for the first 3 the three functions are in exclusive, the range reduction is an additional functionality.
7A ) Relay operating mode display
Procedure:
Keep pressed down, for 4 seconds, the receiver button corresponding to the selected relay, up to the acoustic signal;
subsequently press for an instant P4, within 2 sec.; then still P4 and check the lighting of the leds.
Example : RL1 relay operating mode display
Press for 4 sec. the button P1, for an instant P4, then still P4: the lighting of the leds gives the operating mode set for
RL1.
Impulsive
Bistabile
Delayed
7B ) Change of the relays operating mode
Procedure:
Keep pressed down for 4 sec. the button corresponding to the selected relay up to the acoustic signal; the
corresponding led will light ; within 2 sec. press the button P1 and subsequently press the button (P1, P2 or P3)
according to the new configuration to be planned: the first led will turn off and the second will light on. Example:
Change of the relay RL1 from impulsive to delayed:
7C ) Range reduction programming
Procedure:
Keep pressed down for 4 sec.the button corresponding to the selected relay up to the acoustic signal; the
corresponding led will light; within 2 sec. press the button P1 and subsequently press the button P4. Besides the
corresponding led will light also the led DL4.
Example: Range reduction of RL2 already programmed as impulsive.
7D ) Range reduction removal
Repeat the above procedure and verify that the led DL4 turn-off at the end.
Pag. 16
DL1 DL2 DL3 DL4
Bip1
Press P1 for 4 sec ,
the led DL1
remains lit; the
buzzer sounds
Press P2 for 4 sec ,
Bip1
the led DL2
remains lit; the
buzzer sounds
Impulsive with reduction
Bistable with reduction
Delayed with reduction
Press P3 for 3
Before the end of
the beep, press for
sec., The led DL3
an istant P1, the
lights, the buzzer
led DL1 will turn off
sounds "Beep3"
Press for 4 sec. P4:
Press for an
DL1 and DL4 will light
instant P1, DL2
and the buzzer sounds
turns off
Beep4
T H E S M A R T L I V I N G
DL1 DL2 DL3 DL4
Bip3
Bip4
Fig. 13