1. GENERAL INFORMATION AND SAFETY INSTRUCTIONS

Before installation, please read carefully all the information below and follow all the instructions in the manual. Save this manual
for future reference.
The contents of the manual may not serve as a basis for legal claims.
Unauthorized changes to the product or improper use are not allowed. Intended use includes compliance with the prescribed
operating rules in the manual and legal regulations in the installation region.
The product is not intended for use and storage in acid, saline or explosive environments.
When carrying out work (installation, repair, maintenance, cleaning, etc.), disconnect the product from the mains.
Please observe the safety instructions specified in the legal regulations applicable in the region where the product is
installed. When operating with automatic closure, it is necessary to comply with the standard EN 12453 for safety de-
vices in the region of operation. Qualified personnel must ensure that after a roller shutter system is commissioned, the
standards in force in the region, for example, EN 13659 standards for roller shutters or EN 12635 for gates, are in force.
Radio control is allowed only for installation conditions in which radio interference in the transmitter or receiver does not
cause danger to people, animals or objects, or other protective devices prevent the risk.
Remote control is associated with the risk of injury, and should be performed only with direct visual observation of the
movement of the roller shutter.
The remote control should be stored in such a way as to exclude accidental activation, including by children or animals.
The product is not protected from interference from other radio devices (for example, radio installations operating in the
same frequency band).
2. INTRODUCTION
Receiver CUR (control unit) is designed to control tubular motors of roller shutter systems protecting window, door and gate
openings with the help of buttons on the case or by means of ALUTECH remote controls. It is permissible to connect addi-
tional control and safety devices to the product, such as pushbutton switches, key switches, photocells, optical and resistive
safety edges.

3. TECHNICAL DATA

Please select the optimal model of tubular motor depending on the power of the product, in accordance with the require-
ments of instructions and recommendations of ALUTECH. If necessary, contact the Supplier for advice.
Technical data
Power supply voltage / Frequency
Maximum power consumption in standby mode (without additional devices con-
nected)
Maximum motor output
Flashing lamp power supply
Power supply of additional devices (accessories)
ALUTECH radio frequency
Number of storable remote controls
Protection rating
Operating temperature
Power supply cable section
Additional devices cable section
Dimension (W x H x D)
Weight
These specifications refer to an ambient temperature of 20ºC (±5ºC) and a supply voltage of 230V/50Hz.
5
~230V (+10%, -15%) / 50Hz
1.5W
1500W
~ 230V / max. 100W
12V DC /
max. 100mA
433.92MHz
250
IP54
-20ºС ... +50ºС
2
max. 2.5mm
(22-14AWG)
150 х 100 х 38mm
<0.3kg