s. If this has been done previously, all 4 LEDs will blink to alert
you that you are changing a configuration that then cannot be
restored using the procedures stated here.
LED configuration
Meaning
1 second (default)
5 seconds
All 4 LEDs are flashing:
Different value to the above
The
(PREVIOUS) and
tween the possible values. If you try to go before the first or
after the last one, the speech unit will emit a tone to warn you
that there are no other valid values.
If you start from a configuration with the LEDs flashing, first
pressing the
button (PREVIOUS) will set the first possible
value, while pressing the
possible one.
Pressing
(DEL) takes you back to the previous level,
without saving any changes.
Press
(OK) to confirm what you have chosen.
6. Conversation time
Through the procedure described here, the talk time can only
be set to the values of 2 (default) and 5 minutes. With Save-
Prog other values are possible from 10 to 2540 s. If this has
been done previously, all 4 LEDs will blink to alert you that
you are changing a configuration that then cannot be restored
using the procedures stated here.
LED configuration
Meaning
2 minutes (default)
5 minutes
All 4 LEDs are flashing:
Different value to the above
The
(PREVIOUS) and
tween the possible values. If you try to go before the first or
after the last one, the speech unit will emit a tone to warn you
that there are no other valid values.
If you start from a configuration with the LEDs flashing, first
pressing the
button (PREVIOUS) will set the first possible
value, while pressing the
possible one.
The self-start and response times have not changed, while
with SaveProg the call, self-start and talk times are all set in-
dependently.
EN
(NEXT) buttons change be-
button (NEXT) will set the last
(NEXT) buttons change be-
button (NEXT) will set the last
Pressing
(DEL) takes you back to the previous level,
without saving any changes.
Press
(OK) to confirm what you have chosen.

7. Audio level

The audio level is configurable on 4 levels.
LED configuration
Meaning
Level 1
Level 2
Level 3 (default)
Level 4
Pressing
(DEL) takes you back to the previous level,
without saving any changes.
(OK) to confirm what you have chosen.
Press
8. Reset factory settings / restart
LED configuration
Meaning
Reset factory settings (default)
Restart entire system
Reset external memory
(contacts list, access keys,
remapping)
On confirming "reset factory setting" with
speech unit will emit a continuous tone for 8 s. During this
time you need to press the
step is not completed, the speech unit will go into its rest state.
On confirming "restart entire system", the indoor unit will in-
struct all the devices in the system in which it is installed to re-
start, after which it will itself restart. It is functionally equivalent
to pressing the reset button on the Master speech unit of the
previous generations.
9. Default pushbutton grouping
By confirming with
(OK) you choose how the speech unit
will group the buttons for the calls.
By default the speech units come with the buttons grouped
in twos horizontally to use the single axial button Art. 41110.
This button can actuate one or both mechanical buttons on
the same row.
(OK), the
button (OK) 3 times. If this
27