Herunterladen Diese Seite drucken

Seav LRX 2215 Bedienungsanleitung Seite 6

Elektronische steuereinheit

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
Electronic Control Unit LRX 2215
Electronic control unit for the automation of rolling shutters and sun blinds, with option-
al Wind sensor connection and keypad/radio control operation, for individual and cen-
tralised control.
- Mod. LG 2215 :
- Mod. LRS 2215 :
- Mod. LRS 2215 SET:
- Mod. LRH 2215 :
T
ECHNICAL DATA
- Power supply:
- Motor output:
- Operating temperature:
- Radio receiver:
- Compatible radio controls:
- N° of codes which may be stored:
- N° of Wireless Wind Sensors which may be stored:
- Packaging dimensions:
- Container:
Without radio receiver
433,92 MHz
"Narrow Band" 433.92 MHz
"Narrow Band" 868.3 MHz
230 V~ 50/60 Hz 600 W max.
230 V~ 500 W Max.
-10 ÷ 55°C
see model
12-18 Bit or Rolling Code
Max. 6
Max. 3
110 x 121 x 47 mm.
ABS UL94V-0 ( IP54 )
C
CN1 T
ONNECTION OF
ERMINAL BOARD
1: 230 V line input (Phase).
2: 230 V line input (Neutral).
3: Upward movement motor output.
4: Shared motor output.
5: Downward movement motor output.
C
CN2 T
ONNECTION OF
ERMINAL BOARD
1: Wind sensor input "W".
2: T1 local upward movement button input (NA).
3: Shared GND Signal input.
4: T2 local downward movement button input (NA).
5: T3 general upward movement button input (NA).
6: Shared GND Signal input.
7: T4 general downward movement button input (NA).
8: Earth antenna input.
9: Antenna hot pole input.
I
O
NITIAL
PERATING CONDITION
The equipment can operate using the T1 (Up) and T2 (Down) local command buttons,
the T3 (Up) and T4 (Down) general command buttons, and in conjunction with one or
more radio controls. There is no radio control code stored in the default factory setting.
OPERATIONAL DATA:
T1 – T2 Local command buttons operation:
The following type of operation is obtained by connecting the local command buttons
(normally open) for movement activation to the low voltage inputs T1 – T2:
T1 controls upward movement until the motor running time has elapsed and T2 con-
trols downward movement. If a command is sent in the same direction before the motor
running time has elapsed, the control unit will stop movement; if a command is sent in
the opposite direction before the motor running time has elapsed, the control unit will
invert the direction of the motor.
T3 – T4 General command buttons operation:
The following type of operation is obtained by connecting the general command but-
tons (normally open) for movement activation to the low voltage inputs T3 – T4:
T3 controls upward movement until the motor running time has elapsed and T4 con-
trols downward movement. If a command is sent in the same direction before the motor
running time has elapsed, the control unit will ignore the command; if a command is
sent in the opposite direction before the motor running time has elapsed, the control
unit will invert the direction of the motor.
O
M
PERATION USING DIFFERENT
ODELS OF
Different models of radio control may be programmed: by storing one code (1 button)
a cyclic step by step operation (Up - Stop - Down) is achieved, and by storing two dif-
ferent codes (2 buttons) separate commands are created, one for upward movement
and one for downward movement. Storing a BeFree series radio control (3 buttons)
produces three separate commands: the first button is used for upward movement, the
- 6 -
R
C
ADIO
ONTROL
GB

Werbung

loading

Diese Anleitung auch für:

Lg 2215Lrs 2215Lrs2215 setLrh 2215