XXX = Colors
000 chrome plated
090 chrome plated/gold plated
120 chrome plated/porcelain colour
420 platin
800 steel
810 satinox
820 brushed nickel
830 polished nickel
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice
versa, when mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not possible
Safety stop button not operating
1
English
Cause
Supply pressure inadequate
Regulator filter dirty
Shower filter seal dirty
Backflow preventers dirty or
leaking
Thermostat has not been ad-
justed
Hot water temperature too low
Temperature regulator dirty or
calcified
For new installations: basic
body incorrectly connected
(should be: cold right, hot left)
or installed with 180° rotation
Spring defective
Button calcified
Remedy
Check water pressure (If a
pump has been installed check
to see if the pump is working).
Clean filters
Clean filter seal between sho-
wer and hose
Clean backflow preventers, ex-
change if necessary
Adjust thermostat
Increase hot water temperature
to 42 °C to 65 °C
Clean temperature regulator,
exchange if necessary
Install function block turned
through 180°
Clean spring and/or button,
exchange if necessary