XXX = Colors
000 chrome plated
090 chrome plated/gold plated
120 chrome plated/porcelain colour
420 platin
800 steel
810 satinox
820 brushed nickel
830 polished nickel
Fault
Insufficient water
Crossflow, hot water being forced
into cold water pipe, or vice
versa, when mixer is closed
Spout temperature does not
correspond with temperature set
Temperature regulation not possible
Safety stop button not operating
1
English
Cause
–
Supply pressure inadequate
–
Regulator filter dirty
–
Shower filter seal dirty
–
Backflow preventers dirty or
leaking
–
Thermostat has not been ad-
justed
–
Hot water temperature too low
–
Temperature regulator dirty or
calcified
–
For new installations: basic
body incorrectly connected
(should be: cold right, hot left)
or installed with 180° rotation
–
Spring defective
–
Button calcified
Remedy
–
Check water pressure (If a
pump has been installed check
to see if the pump is working).
–
Clean filters
–
Clean filter seal between sho-
wer and hose
–
Clean backflow preventers, ex-
change if necessary
–
Adjust thermostat
–
Increase hot water temperature
to 42 °C to 65 °C
–
Clean temperature regulator,
exchange if necessary
–
Install function block turned
through 180°
–
Clean spring and/or button,
exchange if necessary