Herunterladen Inhalt Inhalt Diese Seite drucken

Cautions On Safety - Toshiba VN-250TE Installationshandbuch

Lüftungsgerät mit wärmerückgewinnung
Vorschau ausblenden Andere Handbücher für VN-250TE:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
VN250_CON-01EN.fm Page 1 Thursday, September 8, 2005 10:36 AM
■ Read through this "Cautions on Safety" with care before installing the unit.
■ Described below are the way we are stimulating your attention to what you are supposed to observe to prevent dangers to the
users or other people as well as loss to the property.

Cautions on Safety

Never fail to observe the caution items described hereinafter because all of them refer to the critical matters on safety.
The meanings of the marks or indications are described below.
■ The degrees of danger or damage that is likely to occur due to the
wrong use ignoring the indications are categorized for explanation as
marked below.
WARNING
CAUTION
Never fail to ask the sales office from which you bought the unit
or the installation service shop to install the unit. If you install it
by yourself, any inappropriate installation works would cause an
electric shock or a fire.
Carry out the installation works accurately in line with this
installation work manual. Improper practice of installation could
cause an electric shocks or a fire.
Choose the installation place where is endurable in quality as
well as in weight, then install the unit accurately with adequate
strength and completeness of installation in accordance with
the installation work manual. Otherwise, it is likely to cause an
electric shock, a fire, a drop of the unit, thus causing the injury
on the human body.
Carry out electrical work in accordance with the laws and
regulations prevailing in the country concerned, technical
standard and explanation for work, and make absolutely sure
that an exclusive circuit is used. Any insufficient capacity of
power circuit and improper work can result in electric shock and
fire hazard.
Provide an exclusive circuit breaker that can completely break
contacts on all the poles by more than 3mm through direct
connection to the power terminals. Depending upon the
environment for installation, it becomes necessary to install an
earth leakage breaker.
When you want to pierce the metal duct through the metal lath
or the wire lath or the metal plate of the wooden facility, do not
forget to insulate electrically between the duct and the wall.
Otherwise, it would cause an electric shock or an electric
leakage.
Don't use other parts than specified (including the auxiliary
parts) for installation works. If you do not use the specified
parts, it is likely to cause a drop of the unit, a fire, an electric
shock, etc.
Install the outdoor duct in a falling gradient toward the outside
so as to prevent water from coming in. If it is not installed so, the
building is likely to be flooded, wetting the household effects.
Heat-insulate the outdoor duct (including the indoor side, if
necessary) to prevent dewing. If heat insulation is not adequate,
water likely goes indoor and wets the household properties.
When it is high humid and high temperature inside the ceiling, a
ventilation system must be installed inside the ceiling.
Otherwise, it could cause a fire or an electric leakage.
Connect the power line and the connecting line with accuracy
using the specified cables and fix them firmly so as not to put
the outer stress of the cables on the pin connecting area.
Incomplete connection or fixing is likely to cause a heat
generation or a fire.
The column with this mark shows
"Conceivable Threat of Death or Serious
Injury".
The column with this mark shows "Likelihood
of Damage or Loss to Materials only".
WARNING
CAUTION
Never Fail to Observe
■ Kinds of the items to be observed are categorized for
clarification with the following pictorial symbols.
This pictorial indication shows "Prohibited".
This pictorial indication shows "Forced
Execution".
The external air intake opening should be positioned away from
the exhaust openings of combustion gases etc. The intake of
such gases could cause a lack of oxygen in the room.
Netting or something similar should be provided at the external
air intake opening to prevent birds etc. interfering with the unit.
Nests or other foreign objects should be removed. That could
cause a lack of oxygen in the room.
Carry out the ground work. Never connect the ground wire to a
gas pipe, a water supply pipe, a lightning conductor, a ground line
of a telephone, etc. An incomplete ground wire is likely to cause
an electric shock.
When the system is checked and the power cable undergoes
maintenance, stop the operation, and switch the exclusive circuit
breaker "OFF".
Otherwise, it could cause an electric shock.
Install the power line and the connecting line with accuracy so the
power source cover may not float. If the installation of the power
source cover is inappropriate, the pin connection area is likely to
cause a heat generation, a fire and an electric shock due to dust
or powder.
Never install the unit near the place where there is a fear of
leakage of an inflammable gas. If gas happens to leak and stays
around the unit, it is likely to cause a fire.
Don't use the unit at the other voltages than the rated one. It
could cause a fire or an electric shock.
Do not install the unit in locations with large amounts of oily
smoke, such as food preparation areas. It could cause a fire.
Don't install the unit at the place of a high temperature or a flame.
It could cause a heat generation or a fire.
Do not install in locations where harmful or corrosive gasses may
be present (i.e. acidic, alkali, organic solvent, paint gasses etc.
from machinery or factories). Installation in such a location could
cause a gas-poisoning and a fire.
Do not install in locations with high humidity, such as close to
bathroom etc. It could cause an electric shock or an electric
leakage etc.
1

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vn-350teVn-500teVn-800teVn-1ktae

Inhaltsverzeichnis