Care and maintenance

Clean equipment:
Changing the batteries:
Replacing the hose
connection:
Cleaning the screen:
Back-flushing:
Faults - Troubleshooting
Notification in the display
Keep the device clean and remove any dirt immediately.
Clean the device with a damp cloth and a mild cleaning detergent (soap). Do not use any
cleaning agents containing solvents.
To change the batteries, open the battery compartment (3) cover using a screwdriver.
Remove the old batteries.
Insert the new batteries in the battery compartment according to the labelling.
Before screwing the cover back on, make sure that the rubber seal is seated in the provid-
ed groove and is not crushed.
Check whether the O-ring of the cover screw connection is seated in the provided recess.
Correctly attach the cover and screw it back into place.
If the seals are not inserted correctly, this may impair the leak-tightness of the device.
Loosen by turning counter-clockwise
Place the new hose coupling with seal on the thread and tighten in the clockwise direction.
There is a particulate screen in the water supply (5) that holds back larger particles in the
supply water. It is recommended to clean the screen from time to time.
Unscrew the hose connection as described above.
Use pliers to grab the screen at the protruding screen clip and pull it out.
Clean the screen under flowing water and re-insert it.
Screw the hose connection back on.
There is also a screen before the water outlet (7). If the amount of water decreases signif-
icantly, this needs to be cleaned.
The hose must be connected to the water outlet only for this reason and this reason only.
At the same time, the second screen at the water supply (5) must be removed (see above).
Then flush the device backwards to remove the deposits.
Then disconnect the hose and re-insert the screen at the water supply.
Description
BAT notification in the display area
visualizes that the battery is empty
Display of a circumferential line
visualizes that there is no water in
the device
No notification in display after
pressing the "START/PAUSE" button
Rectification
Change the batteries
• Ensure a water supply to the device
• Check whether the device inlet is dirty and
remove any dirt if necessary
• Change the batteries
• If there is still no notification after changing
the batteries, then send in the device for repair