Befehlssysteme zur verwendung im nahbereich
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 45
It is possible to memorise a maximum of
5 master transponder tags to access the
interface remotely and manage user codes.
• On the interface, move the dips of 'S1' to
'ON' according to the following table to
select the memory locations.
dip 1 dip 2
dip 3
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
ON
ON
• Move the tag near to the remote
transponder reader
• The interface will give confirmation by
sounding a 'beep'.
If you have inserted an invalid master code the
interface will sound 5 consecutive beeps.
dip 4
memory
OFF
location 1
OFF
location 2
OFF
location 3
ON
location 4
ON
location 5
3. Memorising user codes locally
• Move jumper J5 on the interface to
'position 1'.
• Press and hold down the button P1 for
at least 2 seconds.
• During the procedure the red led L2 will
light up.
• The buzzer B1 will sound 'beep'.
• The user code memorisation procedure
will be activated with a time maximum
of 30 seconds.
Keypad
• Type the code to memorise into the keypad
(max. 6 digits) and press confirm "
The keypad will sound a two-second long
beep with the green led lit.
The code has been accepted