Herunterladen Inhalt Inhalt Diese Seite drucken

Whale UF2415B Installations- Und Bedienungsanleitungen Seite 3

Hochleistungsfähige frischwasseranlage
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
Figure 3 Overall Dimensions
Plumbing
Attach the inlet pipework to the inlet side of the pumps (Figure 5a). Ensure a double click into the 2 Quick Connect fi ttings.
Attach the outlet pipework to the outlet side of the pumps (Figure 5b). Ensure a double click into the 3 Quick Connect fi ttings.
Secure pipework onto the ¾" (19mm) barb inlet and outlet, using appropriate hose clamps. Inlet and outlet are shown in Figure 5C. Do not overtighten.
Electrical Wiring
The unit must be installed by a qualifi ed electrician in accordance with applicable electrical standards.
WARNING: Fire Hazard. Wiring must comply with applicable electrical standards and include a properly sized fuse or circuit breaker. Improper wiring can cause a fi re
resulting in injury or death.
Switch off the power prior to making connections.
Suggested wiring information shown in Figure 6 is given as a guide only. For full information, refer to the relevant ISO regulations for marine applications and wiring
gauges, connectors and fuse protection.
Figure 5a Inlet Attachment
Outlet
OUTLET
Figure 5c Attaching Freshwater System Plumbing
x4
Fig. 4a
Figure 4a and 4b Securing Kit
Figure 5b Outlet Attachment
Inlet
INLET
3
Fig. 4b

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Uf2425bUf3615bUf3625b

Inhaltsverzeichnis