connection only.
4.3. CONNECTION TO HOT AIR DELIVERY DUCTS
The space heater is set to operate with direct distribution of air.
Nevertheless, it can be connected to appropriately sized air
distribution channels, if required, with maximum diameter and
length as shown in the "TABLE OF TECHNICAL CHARACTERISTICS."
Warning
Before starting the heater, check that the direction of
rotation of the fan matches the direction shown on the fan
itself.
The air distribution channels can be connected by using the various
available accessories, placing the connections on the front, side, or
top as required.
4.4. MOUNTING THE DIESEL BURNER
4.4.1. RIELLO BURNER
• Open the box containing the diesel burner, remove it and keep the
two stickers with lot number for later use;
• Consult the user manual of the burner; and fit the burner fixing
screw onto the burner plate according to the instructions
• Secure the burner plate to the machine by using the 4xM8 screws
and the D8 x D24 washers;
• Insert the burner and fix it to the plate by tightening the nut
supplied onto the screw G;
• Locate the black cable with 7-pin Wieland plug running out of the
electrical panel and insert the plug into the socket H on the
burner;
H
• Remove the burner cover and secure the two hoses to the fittings
of the fuel pump already in place;
• Remove the diesel filter and its bracket and secure the bracket to
machine wall using M5 screws;
L-L 256.00-BM
G
EN
• Remove the nipple and, after wrapping the threaded portion to be
inserted into the filter with Teflon, screw it all the way down;
Warning
The threaded portion with internal conical chamfer M
must protrude in order to allow seal tightening with the
hose.
• Screw the suction hose of the pump onto the fitting M
• Close the burner cover;
• Apply one of the two stickers with the serial number on the
nameplate of the machine characteristic data:
• Apply the second sticker with the serial number on the Assembly
and Installation Declaration contained in the user manual:
L
M
35 / 76