Recommended Hydraulic Supply
Truck Requirements
Installation
Custom Arm Installation

Periodic Maintenance

R
ECOMMENDED HYDRAULIC SUPPLY OPTIONS
G-Series Revolving Clamps can be operated with any of
the hydraulic supply arrangements shown below. Refer
to Cascade Hose & Cable Reel Selection Guide, Part No.
212199, to select the correct hose reel for the mast and
truck. The hose and fitting requirements are:
• Hoses and fittings for the CLAMP function should be
No. 6 with 7 mm (9/32 in.) minimum I.D.
• Hoses and fittings for the ROTATE function should
be No. 8 with 10 mm (13/32 in.) minimum I.D.
A
i
This manual provides instructions for installing Cascade
i
G-Series Revolving Clamps.
Follow the suggested installation procedures for best
1
results. If you have any questions or need more
information, contact your nearest Cascade Service
Department. Refer to back cover.
2
Read the WARNING statements placed throughout this
manual to emphasize safety during clamp installation.
10
IMPORTANT: Field alterations may impair performance
or capability and could result in loss of warranty. Consult
Cascade for any required modifications.
13
Weighted Emission Sound Pressure Level - Weighted
emission sound pressure level (LA) does not exceed 70
dB(A).
Measured Value of Whole Body Vibration - Measured
value of whole body vibration (m/s 2 ) does not exceed 0,5
m/s 2 .
Measured Value of Hand-Arm Vibration - Measured value
of hand-arm vibration (m/s 2 ) does not exceed 2,5 m/s 2 .
CAUTION: Rotate function supply circuit back
pressure exceeding 35 bar (500 psi) can result
in excessive oil heating, reduced attachment
performance and shortened hydraulic system life.
Check for restrictions such as numerous fittings
and fitting/hose sizes less than No. 6 (28G Current
Models) or No. 8. (28G Early Models, 36G-140G).
A and B
RH and LH THINLINE
OR
A
Solenoid Adaption using a RH 6-N-1 Cable-Hose Reel
Group
B
OR (optional)
A and C
RH THINLINE
C
function, and mast single function Internal Hose
Reeving Group for the CLAMP function.
GA0033.eps
2-port hose reel groups.
2-Port Hose Reel Group for ROTATE
6038011-R4 EN