Herunterladen Inhalt Inhalt Diese Seite drucken

Nortel Networks BayStack 10 Installationsanweisungen Seite 29

Power supply unit
Inhaltsverzeichnis

Werbung

208558B.fm Page 29 Thursday, April 26, 2001 11:03 AM
7.
Remove and replace the fans, if necessary.
If any fan becomes inoperative, you must remove and replace it.
Unplug the power cord. If the unit has a UPS installed, turn off power by pressing
the ON and OFF buttons on the front panel of the UPS (refer to the UPS
documentation).
Warning:
You must press the On and Off buttons simultaneously for at least
3 seconds to manually turn off the BayStack 10 PSU with the UPS module
installed.
R emove the power cord from the power source.
Do not touch the fans until they have stopped moving. Injury to
Warning:
fingers could result.
If the BayStack 10 Power Supply Unit is installed in an equipment rack, remove
all components such as the modules, UPS, and battery pack, before you remove
the chassis from the rack.
Remove the fan cover and the metal screen on the right side of the unit, depending
on which fan is not operating.
Be sure not to loosen the screw that attaches the fans to the fan
Caution:
cover.
29

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Nortel Networks BayStack 10

Inhaltsverzeichnis