4) If the mains voltage corresponds to the indications on the label fixed
on the motor, you can plug the unit in. It is prohibited to use
extensions or loose plugs not to standards.
The electrical system the appliance is connected to must be made in
conformity with the laws in force in the country of installation.
It is recommended to have a differential thermomagnetic switch, with
sensitivity equal to 30 mA, upstream from the power socket.
This is, at 50Hz:
According to sub-clause 2.2.2 of EN 61000-3-11:2000 the apparatus
meets the standard if connected to user's supply with the following
maximum permissible system impedance:
Zneutral 50Hz = 0.024W
Zphase 50Hz = 0.037W

INSTALLATION

1) Check that the oil level is always over the
2) Connect the high pressure hose to the
3) Connect the water supply pipe (diameter
WARNING
The earth connection is compulsory
dipstick mark (A).
outlet connection (B).
not lower than 14 mm) to the pump inlet
connection (C). Make sure that the
suction filter of the suction hose
connection is always clean.
filter causes a bad water supply and
consequently a bad pump operation
with the inevitable risk of rapid
wearing out and breakage of internal
mechanisms.