Other alarm parameters
From ALARM menu, press
Select the parameters to be modified by pressing its relevant number.
ALARM TYPE : continuous alarm (with autoreset) or pulse alarm (the alarm
condition is stored waiting for a reset).
BUZZER: to enable/disable a warning buzzer in case of alarm.
ONLY LAST ALARM : if set to YES, when multiple alarms occurs only the most
recent is actioned.
P
confirms the modifications and returns to the previous menu.
Identification texts
From the main menu, press
modification menu.
Each input is identified by a text of maximum 24 characters.
U
D
By
and
select the desired video input.
Changing the input number automatically stores the changes.
$
*
(
By arrow keys
,
,
the text, indicated by a cursor.
E
Pressing
the character indicated by the cursor is added to
the text already displayed.
C
cancels the last character of the text.
M
cancels the whole text.
P
confirms the modifications and returns to the previous
menu.
Videotape recorder and Printer
From the main menu press
RECORDER/PRINTER submenu.
This menu defines the type of VCR trigger control according
to whether the matrix is in state of alarm or not.
1
2
Press
and
to change the type of control.
Menu "Active Imputs" allows to selects the inputs which are
used in the switching cycle controlled by the videotape
recorder.
Press the number 1/16 to enable (
When VCR trigger is not used, the printer control is available:
select the baudrate pressing
P
confirms the modifications and returns to the previous
menu.
6
to access the OTHER PARAMETERS submenu.
4
to access the text
)
,
select the character to add to
5
to access the VIDEOTAPE
)/ disable (
) an input.
X
-
4
Video input
number
Text
Cursor
Page 23
OTHER PARAMETERS
------------------------
1.Alarm type: pulse
2.Buzzer on alarm: NO
3.Only last alarm: NO
------------------------
PROG.End
TITLE OF CAMERA NO.1
------------------------
PRINCES STREET
------------------------
ABCDEFGHIJK|4890.Move
á
|
cursor
LMNOPQRSTUV|
á
.Netx text
|
.Prev.text
â
WXYZ:/.,-
|ENT.Add
|CLEAR.Del
0123456789 |M/A.Del All
|PROG.End
VCR / PRINTER
------------------------
1.If alarm is active:
cycle active inputs
2.If alarm is inactive:
cycle active inputs
3.Active inputs
PRINTER CONTROL IS
NOT AVAILABLE
------------------------
PROG.End