Parameter 9 – automatic restart after power outage:
If the position "1" is set, the equipment will start automatically after the power supply has been resumed. If "0" is set, the equipment will await
operator's intervention. It is recommended not to change the factory setting.
Parameter b – fi ltration pump mode:
If the fi ltration pump control system is connected to relevant terminals, the heat pump will control the operation of fi ltration pump as required.
Parameter 0
Water target temperature setting
in cooling mode 15 ~ 45°C
(factory setting 27°C)
Parameter 4
Switch-on temperature
for defrosting
(factory setting -5°C)
Parameter 8
Protection of compressor outlet
temperature 95 ~ 110°C
(factory setting 95°C)
10
Parameter 1
Water target temperature setting
in heating mode 15 ~ 45°C
(factory setting 27°C)
Parameter 5
Switch-off temperature
for defrosting
(factory setting 15°C)
Parameter 9
Automatic restart after power
outage 0/1
(factory setting 1)
Parameter 2
Water target temperature setting
in automatic mode 15 ~ 45°C
(factory setting 27°C)
Parameter 6
Defrosting time
(factory setting 6 min)
Parameter A
Mode selection (heating /
heating & cooling)
(factory setting: heating & cooling)
Parameter 3
Time interval for check for frosting
(factory setting 40 min)
Parameter 7
Temperature of protection
from low ambient temperature
(factory setting -7°C)
Parameter b
Filtration pump mode 0/1
(factory setting 1)