Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications; Installation - Emerson FB2100 Anleitung

Inhaltsverzeichnis

Werbung

Safe Use Instructions – Emerson FB2100 Flow Computer
Part D301770X012
September 2018

Specifications

POWER
Operating Range: 10.5 Vdc to 30 Vdc (10W max power)
ENCLOSURE
Housing:
Powder-coat aluminum, with lockable door.
Compression-molded fiberglass, with lockable door
ENVIRONMENTAL
Operating Temperature:
Non-sparking (Ex nA): –25C to +55C.
Storage Temp.: –40C to +85C.
Operating Humidity: 5-95% non-condensing per IEC
60068-2-3.
WEIGHT
6.94 kg (15.3 lbs) (fiberglass enclosure)
10.75 kg (23.7 lbs) (aluminum enclosure)
APPROVALS
Evaluated to the following European Standards (EMC):
EN 61326-1:2013 (Emissions)
EN 61326-2-3:2013 (Immunity)
Immunity
EN 61000-4-2 (Electro Static Discharge)
EN 61000-4-3 (Radiated Immunity)
EN 61000-4-4 (Fast Transients)
EN 61000-4-5 (Surges)
EN 61000-4-6 (Conducted RF)
EN 61000-4-8 (Power Frequency Magnetic Field)
EN 61000-4-17 (Voltage Ripple)
EN 61000-4-29 (Voltage Dips and Interrupts)
Evaluated to the following Approval Standards:
Directive 2014/34/EU
EN 60079-0:2012+A11:2013
EN 60079-15:2010
Evaluated to the following Standards (IEC):
IEC 60079-0 (2011), 6
th
IEC 60079-15 (2010), 4
th
Product Markings for Hazardous Locations:
Ex nA IIC T4 Gc (–25°C ≤ T
II 3 G
Cert. No. DEMKO 16 ATEX 1579X
2
Edition
Edition
≤ +55°C),
amb
DANGER
When installing units in a hazardous area, make sure all
installation components selected are labeled for use in
such areas. Installation and maintenance must be
performed only when the area is known to be non-
hazardous. Installation or maintenance in a hazardous
area could result in personal injury or property damage.
Always turn off the power to the FB2100 before you
attempt any type of wiring. Wiring of powered
equipment could result in personal injury or property
damage.
To avoid circuit damage when working
inside the unit, use appropriate electrostatic discharge
precautions, such as wearing a grounded wrist strap.
Check the input power polarity before connecting power
to the FB2100. Wiring of powered equipment could result
in personal injury or property damage.
The following tools are required for installation,
maintenance, and troubleshooting:
Personal computer running Microsoft
Professional or Windows 8.1 Pro, or Windows 10 Pro
and Emerson Field Tools configuration software
(providing FBxConnect™).
#1 and #2 Phillips (cross-head) screwdriver.
3 mm (1/8-inch) flat-head screwdriver.
Unpacking
You receive the FB2100 in a box. Remove it from the box.
Examine the packing list carefully to ensure you have all
components.

Installation

1. Find a suitable location for the FB2100. When
selecting an installation site, be sure to check all
clearances. The FB2100 housing is designed to
withstand a variety of inclement conditions. The
optional LCD should be visible and accessible for the
on-site operator.
www.Emerson.com/RemoteAutomation
®
Windows
®
7

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis