Herunterladen Inhalt Inhalt Diese Seite drucken

Declaration Of Conformity - Emerson FB2100 Anleitung

Inhaltsverzeichnis

Werbung

Emerson FB2100 Flow Computer
Figure 1. Emerson FB2100 Label
(Non-sparking with Integral Sensor)
Use this safe use instructions (SUI) document with the
Emerson FB2100 Flow Computer Instruction Manual (part
D301783X012). For full cautions and descriptions of
installation and troubleshooting procedures, refer to this
manual. If you require training for this product, contact
your local sales office.
The Emerson FB2100 Flow Computer (or "FB2100") with
ATEX approval may be ordered with any of the optional
communications or I/O modules listed in the product data
sheet Emerson FB2100 Flow Computer (part
D301791X012).
Figure 2. Emerson FB2100 Label
(Non-sparking without Integral Sensor)

Declaration of Conformity

Hereby, Remote Automation Solutions declares that the
Emerson FB2100 Flow Computers are in compliance with
the essential requirements and other relevant provisions
of European Directives 2014/30/EU (EMC), and
2014/34/EU (ATEX).
Remote Automation Solutions
Safe Use Instructions – Emerson FB2100 Flow Computer
Specific Conditions of Use
Use equipment in an area of not more than pollution
degree 2.
Make provisions to ensure, in the event of transient
disturbances, that the rated voltage does not exceed
140% of the peak rated voltage.
Lead acid battery and solar power options are not for
use in ATEX applications.
Impact tests on the display were conducted based on
Group II values for the low risk of mechanical danger,
in accordance with Table 13 of both EN 60079-
0:2012+A11:2013 and IEC 60079‐0 6
flow computers with displays in areas where the risk of
impact is low.
In Zone 2 installations, ensure that the flow computer
is installed and used to prevent the danger of
electrostatic charges.
The FB2100 enclosure requires a tool to open. Refer to
the Physical Security section in Chapter 1 of the
Emerson FB2100 Flow Computer Instruction Manual
(part D301783X012) for further details.
Table 1
for replacement parts.
Table 1. Replacement Parts
Replacement Part
Kit Number
8-Channel Expansion
400217010-KIT
I/O Board
6-Channel Expansion
400215010-KIT
I/O Board
HMI Module Display
399379-01-0,
621627011-KIT,
Assembly
399380-01-0,
621627020-KIT
400210010-KIT,
I/O Termination
Board
358807010-KIT
CPU Enclosure and
621673-01-0,
621674-01-0,
Electronics
621675-01-0,
621676-01-0,
621678-01-0,
400209010-KIT,
399260-01-0,
399264-01-0,
400211010-KIT
Sensor
Variable Kit Number
399291-01-0,
Door Accessories
399267-01-0,
399266-01-0,
621661010-KIT,
399394-00-0
395828-01-0
Relay
395620-03-1
Coin Cell Battery
Part D301770X012
September 2018
th
Edition. Install
Field Replacement
Guide document
number
D301804X012
D301803X012
D301822X012
D301805X012
D301803X012
D301843X012
D301825X012
D301847X012
D301855X012

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis