8.- Technical data

AKO-522104
Power supply ........................................................................................................................90-260 V~ 50/60 Hz
Maximum input power ................................................................................................................................20 VA
Accumulators ..................................................................................................................................Ni-MH 1.6 Ah
Lighting + alarm duration ..............................................................................................................> 10 Hours (*)
No. of inputs.......................................................................................................................................................4
Compatibility of inputs.............................................................................................................AKO-52062 button
Gas alarm/prealarm relay...........................................................................................SPST 230 Vac, 8 A, cos j =1
Trapped person alarm relay .....................................................................................SPDT 230 Vac, 16 A, cos j =1
Working ambient temperature ..........................................................................................................0 ºC to 50 ºC
Storage ambient temperature .........................................................................................................-30 ºC a 70 ºC
Protection degree .........................................................................................................................................IP 65
Installation category .....................................................................................................................II s/EN 61010-1
Pollution degree ...........................................................................................................................II s/EN 61010-1
Double isolation between power supply, secondary circuit and relay output.
Sound power..........................................................................................................................90 dB(A) at 1 metre
AKO-52214
Power supply..................................................................................................................................15 Vdc ±3 Vdc
Consumption Typical
Maximum AKO-52213/14 ..............................................................................................100 mA
Working ambient temperature .......................................................................................................-20 ºC to 50 ºC
Storage ambient temperature .........................................................................................................-20 ºC a 60 ºC
Range of maximum allowed humidity .............................................................5 - 85% RH (without condensation)
Protection degree .........................................................................................................................................IP 40
Sensor type AKO-52211/12/13/14 ..............................................................Sn02 (Metal Oxide Semiconductor)
AKO-52215 ...................................................................NDIR (Non-Dispersive Infrared Technology)
Display range (AKO-52215) ............................................................................................................0 - 9999 ppm
Life.........................................................................................Depending on temperature and humidity conditions
EMC Standard ......................................................................................................................................EN 61000
AKO-52062
Power supply..................................................................................................................................15 Vdc ±3 Vdc
Working ambient temperature .......................................................................................................-50 ºC to 50 ºC
Storage ambient temperature .........................................................................................................-50 ºC a 70 ºC
Protection degree ..........................................................................................................................................Ip65
*Duration with 4 push-buttons connected to an ambient temperature of 5 to 30 ºC.
Only S1 and S2:...................................AKO-52062 button or AKO-5221x gas detector
AKO-52213/14 ................................................................................................75 mA
AKO-52215......................................................................................................30 mA
AKO-52215......................................................................................................50 mA
25

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ako-522044Ako-522104Ako-522054Ako-52214

Inhaltsverzeichnis