Herunterladen Inhalt Inhalt Diese Seite drucken

RAIS VISIO 1 Bedienungsanleitung Seite 167

Attika feuerkultur
Vorschau ausblenden Andere Handbücher für VISIO 1:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 75
English
VISIO 1 - installation distances - panels
ATTENTION!
Insulated chimney (acc.)
all the way down to the
collar
Reflector plate
Distance from reflec-
tor to back wall (see
table)
Panel type
12,5 mm Fermacell with
25 mm
mineral wool
50 mm calcium silicate bords
attika
RAIS/
Clearance height above burn-
ing chamber min. 698 mm.
Distance from front
glass to furniture min.
1400 mm
Distance to back wall
75 mm
62,5 mm
- User manual for VISIO
Convection area is placed
just below the sloped plate.
To guide the hot air out of
the convection outlets, RAIS
recommends to mount a
sloped, non-combustible and
insulating plate (Fermacell
+ mineral wool or similar)
above the outlets.
Fermacell is facing down.
Installation height
min. 385 mm
31

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Visio 2Visio 3

Inhaltsverzeichnis