FOR THE CORRECT FUNCTIONING OF THE WOOD SIDE THE CAST IRON GRID INSIDE THE COMBUSTION CHAMBER IS POSITIONED AS
FOLLOWS PAYING ATTENTION NOT TO PLACE IT UPSIDE DOWN IN ORDER TO PREVENT THAT THE ASH PACKS TOGETHER AND DOES NOT

Boiling

If for any reason (power cut, pump fault, too much wood etc...), the water content in the thermo stove should reach boiling point, immediately follow the
operations below:
Open a domestic hot water cock and leave the water to run until the temperature of the thermo stove lowers (only mod. with set-up);
Close the wood side combustion regulator completely.
After having ascertained the reason for the high temperature, wait for every thing to go back to normal (temperature below 60°C).
After boiling it is good practice to rearm the safety thermostat positioned behind the thermo stove.

Ignition of the thermo stove (PELLET SIDE)

BEFORE SWITCHING THE THERMO STOVE ON, MAKE SURE THAT THERE IS WATER IN THE SYSTEM AND INSIDE THE BOILER BODY.
Pressing button 4 (ON/OFF) for a few seconds allows to start the thermo stove ignition cycle. After a few seconds the display shows "Fun ASP", the flue gas
intake device switches on and, after 10 seconds, the ignition resistance switches on along with the motor reducer that loads the pellets. In this phase, "LoAd
PELL" appears. After max 13 minutes (Pr01), with the flame on, the board displays "FirE on" and remains in this phase for about 5 minutes (Pr02)in order
to allow the fire to expand uniformly along the entire brazier. After these phases, which have complete duration of 18 minutes, the thermo stove goes into
work mode at the pre-set power.
It is recommended to make the thermo stove function at power 3 for a few minutes before passing to maximum power.
In the case of no pellet ignition, the thermo stove goes into alarm conditions (ALARM no FIRE).
The alarm may occur also if the brazier is dirty; in this case, clean the brazier and re-start the thermo stove.
ATTENTION!!!
FALL INSIDE THE ASH DRAWER.
Loosen the black cap behind the thermo stove, press the button under the cap.
At this point, the thermo stove can be switched back on.