EASY MAINTENANCE

Monthly cleaning and regular maintenance may help extend the life of your cushion. During
cleaning, component inspection is recommended. Check the covers for tears and excessive wear.
To Clean Cover
Remove the cover from the base. Turn the cover inside out and machine wash in warm water and
drip or tumble dry on low heat. No ironing is required.
NOTE– Do not dry clean covers or use industrial washers and dryers to clean the cover. Do not
steam autoclave. Do not bleach.
After washing, fit cover back over cushion base and gel pad. Ensure the back of the cover match-
es up to the back of the foam base and gel pad assembly.
NOTE– If utilized in an institutional setting, write the resident's name with a permanent marker
on the content label of the covers. This will help to ensure the return of the covers after
washing.
Use only Jay-designed covers in conjunction with the J-Gel Cushion.
To Clean Foam Base
Remove the cover and gel pad from the foam base. Wipe with warm water and soap. Wipe off
with a clean cloth.
NOTE– Avoid submersion of the foam base in water.
Reinstall the gel pad, then fit cover back over foam base. Ensure the back of the cover matches
up to the back of the foam base and gel pad assembly.
To Clean Gel Pad Overlay
Remove the cover and gel pad from the foam base. Recommend use of a 1:10 solution of bleach
and water to clean the gel cube pad surfaces. You may also use any conventional hospital
approved topical equipment cleaners and disinfectants that do not contain alcohol. (Never clean
any surfaces of cushion with alcohol). Wipe off with a clean cloth. The gel overlay may also be
cleaned with warm water and soap. Autoclaving and gas sterilization are not recommended.
Always thoroughly rinse gel pad with clear water before placing back into service. This helps
eliminate the possibility of skin irritation due to cleaning solution residue.
Reassembling the J-Gel Cushion After Cleaning
Make sure cover, foam base and gel pad overlay are completely dry before reassembling. Orient
the front and back of each component per the labels on each, then attach the gel pad overlay
using the Velcro® strips as location indicators. The gel pad should fit symmetrically over the foam
base. Lastly, replace cover over entire assembly. Ensure the back of the cover matches up to the
back of the cushion/gel assembly.
Repairs
Manufacturer offers a repair kit with instructions for the Gel cube pad.
XT4205 Rev. B
E n g l i s h I n s t r u c t i o n s
E n g l i s h I n s t r u c t i o n s

LIMITED WARRANTY

Sunrise Medical guarantees its products to be free from defects in materials and workmanship for
a specific period of time from the date of purchase.
• The J-Gel Cushion is guaranteed for 2 years from date of purchase.
Sunrise Medical will, at its option, repair or replace your cushion without charge. The warranty
does not apply to punctures, tears or burns, or to the cushion cover.
Claims and repairs should be processed through the nearest authorized Sunrise Medical– Jay
equipment supplier. Except for express warranties made herein, all other warranties including
implied warranties of merchantability and warranties of fitness for a particular purpose are exclud-
ed. There are no warranties which extend beyond the description on the face hereof. Remedies for
breach of express warranties herein are limited to repair or replacement of the goods. In no event
shall damages for breach of any warranty include any consequential damages or exceed the cost
of non-conforming goods sold.
Maximum user weight:350 lbs (158 kg)
NOTE–
The J-Gel Pad overlay is intended to be used in conjunction with the J-Gel foam base. Use of the
J-Gel pad overlay without the J-Gel foam base will impede the use for which the cushion is
intended. Use of the J-Gel pad overlay without the J-Gel foam base will void the warranty and
the manufacturer assumes no liability.

REPAIR KIT M4204 INSTRUCTIONS:

1. Area to be repaired must be clean and dry before applying repair tape.
2. Any sticky surface exposed or damaged may be cleaned with mineral oil. Remove mineral
oil residue using warm, soapy water. Dry surface completely before applying tape.
3. Measure damaged area and cut repair tape to size. Allow for 6 mm overlap on all sides.
4. Carefully peel back approximately 12 mm of brown backing paper and crease it.
5. Carefully apply exposed portion of clear tape to damaged surface. Push out any air bubbles
which may be trapped beneath the tape.
6. Continue to carefully apply repair tape while slowly removing paper backing. Push out any
air bubbles.