3D Kamera
Minimum and maximum values of device config parameters
The minimum and maximum values of the device configuration parameters are:
Parameter name
ActiveApplication
PcicProtocolVersion
IOLogicType
IOExternApplicationSwitch
SessionTimeout
13.6.6 Device/Network Config Object
saveAndActivateConfig
Method name
Description
Input parameters
Output parameters
13.6.7 Application Config Object
save
Method name
Description
Input parameters
Output parameters
forceTrigger
Method name
Description
Input parameters
Output parameters
Validate
Method name
Description
Input parameters
Output parameters
Fault scenarios
52
Minimum value
0
1
0
0
5
saveAndActivateConfig
Reinitialise the network interface so that it uses the configuration
which was set by the other RPC methods.
There will be no XMLRPC reply because the network interface is
instantly reset.
none
Empty string (compatibility with classic XmlRPC-client)
save
Stores current configuration in persistent memory.
This is also be possible if the application is not yet in an "activatable"
status.
none
Empty string (compatibility with classic XmlRPC-client)
forceTrigger
Executes a software trigger of currently active application.
none
Empty string (compatibility with classic XmlRPC-client)
validate
Validates the application. This means it checks if the application can
be activated.
none
Array of fault structs (Id: int, Text: string)
none
Maximum value
32
4
1
3
300