Werbung

disablePassword
Method name
Description
Input parameters
Output parameters
save
Method name
Description
Input parameters
Output parameters
Parameters of device config
Methods for parameter access are defined here:
Parameter name
Name
Description
ActiveApplication
PcicTcpPort
PcicProtocolVersion
IOLogicType
IODebouncing
IOExternApplicationSwitch
disablePassword
Disables the password protection.
Making this change persistently requires to call "save" on device
config.
none
Empty string (compatibility with classic XmlRPC-client)
save
Stores current configuration in persistent memory.
If this is not called after changing device parameters (via
setParameter), changes will get lost on reboot.
none
Empty string (compatibility with classic XmlRPC-client)
Data type
Description
String (utf8)
User-defined name of the device (max. 64 characters).
String (utf8)
User-defined description of the device
(max. 500 characters).
Int
Index of active application
*has limits
This applies only to RUN mode:
* defines the application active on startup (if static-
application switching is disabled)
* contains the current active application (could also be
changed via PCIC command)
* 0 means no application is active
Int
TCP/IP port for PCIC connections.
Int
Sub-protocol of PCIC, see specification of PCIC.
*has limits
Int
Defines logic type of all digital pins.
*has limits
Allowed values:
0: NPN
1: PNP
Bool
Applies to all inputs
Int
Allowed values:
*has limits
0: off
1: static via I/O
2: pulse driven via I/O
3: pulse driven via trigger
3D Kamera